724264
10
Zoom out
Zoom in
Vorherige Seite
1/24
Nächste Seite
Check the mains lead at regular intervals for
signs of defects or damage. A damaged mains
lead may only be replaced by an electrician or
ISC GmbH in compliance with the relevant
regulations.
The equipment is not designed for installation in
laundries.
The equipment must be positioned in such a way
that the mains plug is accessible at all times.
The temperature in the cooling circuit may
become very hot. For this reason keep all cables
away from the copper lines.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the “Sleep”
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.
2. Items supplied
Split 900 Flat EQ C+H
1 indoor device (box 1, art. no. 23.654.54)
1 outdoor device (box 2, art. no. 23.654.55)
1 set of installation accessories (for details, see page
16)
Split 1200 Flat EQ C+H
1 indoor device (box 1, art. no. 23.654.56)
1 outdoor device (box 2, art. no. 23.654.57)
1 set of installation accessories (for details, see page
16)
3. Technical data
Split 900 Flat EQ C+H
Cooling capacity 2600 watts
Heating capacity 2800 watts
Energy efficiency A (EER 3.25/COP 3.26)
Air capacity 450 m
3
/h
Absorbed humidity (30°C/80% RH) 1.0 l/h
Timer 24 h
Operating voltage 230 V ~ 50 Hz
Socket fusing 10 A
Nominal power consumption, cooling 960 watts
Nominal current consumption, cooling 4.17 A
Nominal power consumption, heating 1120 watts
Nominal current consumption, heating 4.87 A
Compressor Rotary piston
Compressor starting current 17 A
Outdoor operating temperature 0 - +43 °C
Indoor operating temperature +16 - + 30°C
Fluid line Ø A 6.35 mm
Suction pipe Ø A 12.7 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 1100 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 38 dB (A)
Outside ≤ 53 dB (A)
Dimension Inside 100,5 x 29 x 15 cm
Dimension Outside 84,8 x 54 x 32 cm
Weight Inside 16 kg
Weight Outside 40 kg
Split 1200 Flat EQ C+H
Cooling capacity 3500 watts
Heating capacity 3700 watts
Energy efficiency A (EER 3.21/COP 3.30)
10
GB
Anleitung_SPLIT_900-1200_E+Q_C_H_GB:_ 18.01.2008 7:26 Uhr Seite 10
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Einhell Split 1200 FLAT EQ C-H wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Einhell Split 1200 FLAT EQ C-H

Einhell Split 1200 FLAT EQ C-H Bedienungsanleitung - Deutsch, Französisch - 72 seiten

Einhell Split 1200 FLAT EQ C-H Bedienungsanleitung - Französisch - 24 seiten

Einhell Split 1200 FLAT EQ C-H Bedienungsanleitung - Italienisch - 72 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info