앬 Check the mains lead at regular intervals for
signs of defects or damage. A damaged mains
lead may only be replaced by an electrician or
ISC GmbH in compliance with the relevant
regulations.
앬 The equipment is not designed for installation in
laundries.
앬 The equipment must be positioned in such a way
that the mains plug is accessible at all times.
앬 The temperature in the cooling circuit may
become very hot. For this reason keep all cables
away from the copper lines.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
Packaging:
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
Tips on saving energy
Only use the air conditioner when you really need to.
Do not select too high a temperature for heating or
too low a temperature for cooling. Select the “Sleep”
function during the night.
Close all windows, doors and Venetian blinds in
order to reduce incoming sunlight as far as possible.
Principle of operation for cooling
Heat is extracted from the air in the room by the air
heat-exchanger (evaporator) in which the coolant
circulates. This air is conveyed to the outside air
heat-exchanger (condenser).
This gives off heat to the outdoor air. Electrical
energy is required for this. In certain circumstances
condensation may form on the evaporator on the
indoor unit, which will be removed by the
condensation hose.
2. Items supplied
Split 900 Flat EQ C+H
1 indoor device (box 1, art. no. 23.654.54)
1 outdoor device (box 2, art. no. 23.654.55)
1 set of installation accessories (for details, see page
16)
Split 1200 Flat EQ C+H
1 indoor device (box 1, art. no. 23.654.56)
1 outdoor device (box 2, art. no. 23.654.57)
1 set of installation accessories (for details, see page
16)
3. Technical data
Split 900 Flat EQ C+H
Cooling capacity 2600 watts
Heating capacity 2800 watts
Energy efficiency A (EER 3.25/COP 3.26)
Air capacity 450 m
3
/h
Absorbed humidity (30°C/80% RH) 1.0 l/h
Timer 24 h
Operating voltage 230 V ~ 50 Hz
Socket fusing 10 A
Nominal power consumption, cooling 960 watts
Nominal current consumption, cooling 4.17 A
Nominal power consumption, heating 1120 watts
Nominal current consumption, heating 4.87 A
Compressor Rotary piston
Compressor starting current 17 A
Outdoor operating temperature 0 - +43 °C
Indoor operating temperature +16 - + 30°C
Fluid line Ø A 6.35 mm
Suction pipe Ø A 12.7 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 410 A
Refrigerant filling capacity 1100 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 38 dB (A)
Outside ≤ 53 dB (A)
Dimension Inside 100,5 x 29 x 15 cm
Dimension Outside 84,8 x 54 x 32 cm
Weight Inside 16 kg
Weight Outside 40 kg
Split 1200 Flat EQ C+H
Cooling capacity 3500 watts
Heating capacity 3700 watts
Energy efficiency A (EER 3.21/COP 3.30)
10