3. Proper use
The compressor is designed for generating
compressed air for tools operated by compressed
air.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Mains connection: ........................ 230 V ~ 50 Hz
Motor rating: ........................................... 1500 W
Compressor speed min
-1
: ........................... 2850
Operating pressure bar: ............................max. 8
Pressure vessel capacity (in liters): ................ 24
Theoretical suction rate l/min.: ..................... 230
Output (compressed air) at 7 bar: ....83 liters/min
Output (compressed air) at 4 bar: ..102 liters/min
Sound power level L
WA
in dB: .......................... 94
K
WA
uncertainty ........................................2.14 dB
Sound pressure level L
pA
in dB: ...................... 72
K
pA
uncertainty ........................................2.14 dB
Protection type: ........................................... IP20
Weight of the unit in kg: ................. approx. 25 kg
Oil quantity: ............................. approx. 0.23 liters
Noise
The noise emission values were measured in ac-
cordance with EN ISO 2151.
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Examine the machine for signs of transit da-
mage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the
working consumer.
Avoid long air lines and long supply lines (ex-
tensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet
rooms.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
The oil level in the compressor pump has to
be checked before putting the equipment into
operation.
The equipment must be set up where it can
stand securely.
Use flexible hoses in order to prevent trans-
mitting unacceptable loads to the pipeline
system at the connection between the com-
pressor system and the pipeline system.
It is essential to use separators, traps and
drains which process the liquids produced by
the compressor before the compressor sys-
tem is put into operation.
Supply hoses at pressures above 7 bar
should be equipped with a safety cable (e.g.
a wire rope).
Anl_TE_AC_230_24_SPK1.indb 19Anl_TE_AC_230_24_SPK1.indb 19 02.07.15 15:2302.07.15 15:23
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

einhell-te-ac-230-24

Suche zurücksetzen

  • Der Kompressor stoppt bei 6,5 Bar! Wo kann ich den Druck höher stellen? Eingereicht am 18-7-2019 14:30

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Einhell TE-AC 230-24 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Einhell TE-AC 230-24

Einhell TE-AC 230-24 Bedienungsanleitung - Deutsch, Holländisch, Französisch, Italienisch, Spanisch - 60 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info