INSTALLATION
REMARKS ON INSTALLATION
REMARKS ON INSTALLATION
Note that:
Note that:
the appliance must be installed by authorised
the appliance must be installed by authorised
technical personnel
technical personnel
the appliance must be installed and operated
the appliance must be installed and operated
in compliance with local and national laws and
in compliance with local and national laws and
European regulations
European regulations
if installed in a condominium, the appliance must
if installed in a condominium, the appliance must
be approved by the administrator.
be approved by the administrator.
Here are a few general instructions, although
Here are a few general instructions, although
these do not obviate the need to comply with local
these do not obviate the need to comply with local
regulations and do not a ect the installer’s liability for
regulations and do not a ect the installer’s liability for
the installation.
the installation.
FLUE SYSTEM
FLUE SYSTEM
(
(
Fumes duct, ue and chimney pot
Fumes duct, ue and chimney pot
)
)
This chapter has been drawn up pursuant to
European regulations EN 13384, EN 1443, EN 1856
and EN 1457. The installer must observe both these
and any other local regulations. This manual does
not in any way substitute such regulations.
The product must be connected to a ue system which
ensures that the fumes produced by combustion are
expelled in complete safety.
Before positioning the appliance, one must check
that the ue is suitable.
FUMES DUCT, FLUE
FUMES DUCT, FLUE
The fumes duct
(which connects the combustion
(which connects the combustion
chamber smoke outlet with the ue)
chamber smoke outlet with the ue) and the ue itself
must, among other regulatory requirements:
receive the fumes from a single product (the
outlets of multiple appliances may not be
conveyed into a single ue)
have a mainly vertical course (no horizontal
sections and bends of over 45° are allowed)
have no downwards sloping sections
have a preferably circular internal cross section
and nevertheless with a ratio of the sides of less
than 1.5
terminate at roof level with a proper chimney pot:
the ue may not discharge directly on the wall
or into an enclosed space, even if the space in
question is open to the sky
be made of material with rated re reaction class
A1 as per UNI EN 13501 or analogous national
regulations
be
certi ed, with a chimney plate if metal
keep the initial section.
Checking the suitability of the installation space
The room must have a volume of at least 40 m3
The appliance may not be installed in a
bedroom, bathroom or in the same room as other
equipment which draws air for combustion from
the room itself, or in any area with an explosive
atmosphere. Any extraction fans operating in the
same room/area of the product, may a ect its
draw
In Italy, check the compatibility pursuant to UNI
10683 and UNI 7129 in the presence of gas- red
products
The oor must be able to bear the weight of the
product and its accessories.
Protection from heat and safety clearances
The surfaces of the building adjacent to the product
must be protected against overheating.
The insulation to be used will depend on the type of
surface in question.
Observe the following minimum distance from
in ammable
materials
- 15 cm from the non-glass rear of the appliance
- 80 cm from the glass sides. Do not place any
in ammable materials at shorter distances.
Power lines
Power lines
no power lines must be present in the walls
no power lines must be present in the walls
and in the ceilings within the recessed
and in the ceilings within the recessed
area of the product
area of the product
PLEASE NOTE:
If the replace is not level there may
be problems with the door’s sliding
movement.
14

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für EK63-EdilKamin Firek 3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von EK63-EdilKamin Firek 3

EK63-EdilKamin Firek 3 Bedienungsanleitung und Installationsanweisung - Französisch - 28 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info