Operation
Main functions of the control panel
Button Action Procedure Display / Function
Setting up the required
room temperature
HK2 jointly with HK1
Turn the rotating button left or right
Turn the rotating button again for
storing with OK button
or wait for 5 sec.
or push
comfort target value with blinking temperature display
blinking temperature display in steps of 0.5° centigrade, from 10.0 to 30°C
Comfort value active
Comfort value not active
- Basic display appears after 3 sec.
Setting the required room temperature
for HK1 or HK2
or
2nd HK independent of HK1
Turn rotating button left/right
Then push OK
Turn rotating button left/right
Save with OK button
or wait for 5 sec.
or push
Select heating circuit
Heating circuit active
blinking temperature display in steps of 0.5° centigrade, from 10.0 to 30°C
Comfort target value active
Comfort target value not active
- Basic display appears after 3 sec.
Switching warm water operations ON
or OFF
Push button Warm water operation ON / OFF
(segmented bar under symbol for warm water visible/invisible)
- ON: Warm water preparation according to switching program
- OFF: No warm water preparation
- Safety function active
Change operating mode
Factory setting
1 x short push of button and then
once more, short push of button
Automatic operating mode ON, with:
- heating operation according to timer program
- Temperature target values according to heating program
- Safety function active
- Summer/Winter - automatic switching active
- ECO functions active
(segmented bar under corresponding symbol visible)
Continuous COMFORT heating ON, with:
- Heating operation without timer program, at comfort target value
- Safety function active
Continuous REDUCED heating ON, with:
- Heating operation without timer program, at reduced target value
- Safety function active
- Summer/Winter - automatic switching active
- ECO functions active
Automatic safety mode ON, with:
- Heating operations switched off
- Temperature according to frost protection value
- Safety function active
Control stop function
1 x push button (> 3 sec)
push button once more (> 3 sec)
304: Control stop function Set target value
Basic display appears after 3 sec.
Display of various
information
1 x push button
push button again
push button again
Push button
INFO section is displayed
- Boiler status - Room temperature
- Room temperature minimum
- Warm water status - Room temperature maximum
- Status heating circuit 1 - Outdoor temperature
- Status heating circuit 2 - Minimum outdoor temperature
- Maximum outdoor temperature
- Time / date - Water temperature 1
- Error message - Boiler temperature
- Maintenance report - Flow temperature
(Display of the information lines depends on the conguration)
Back to basic display; INFO segment is suppressed
Operating mode according to
target values that are
set manually
Change of the factory setting
for boiler temperature
short push of button
short push of button
short push of button
Rotating button turn -/+
short push of button
short push of button
short push of button
Manual operating mode ON (spanner symbol is visible)
- Heating operations at preset boiler temperature (factory setting = 60°C)
301: Manual operation mode Set target value for manual
operation?
Blinking temperature display
Set required target value
Boiler status
Manual operating mode OFF (spanner symbol disappears)
De-aeration function 1 x push button (> 3 sec)
push button once more (> 3 sec)
312: De-aeration function ON
De-aeration function OFF
Activation of chimney sweep function Push button (> 3 sec)
push button once more (> 3 sec)
Chimney sweep function ON
Chimney sweep function OFF
Short-term reduction of room
temperature at QAA75 / 78
Push button
push button again
Heating at reduced target value
Heating at comfort target value
RESET
Reset button Push button (< 3 sec.) push button
again > 3 sec.
Facility is manually locked, unreleased equipment is unlocked, alarm bell
disappears
= Conrmation
= Abort or back to basic display
47

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elco THISION S PLUS Combi wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info