The type and nature of wall construction material, the appliance dimensions,
the way of fixing it, the location of its fixing elements and tubes, its protection
against dripping water must be taken into account when choosing the proper
place for installation. The protection against dripping water is marked on the
appliance production plate with its serial number . The appliance must be
mounted where it is protected against water dispersion or water pouring
over . In order to reduce heat loss it is recommended to keep minimum
distance between the heater and the places where the hot water is used.
If you purchased a water heater with factory-fitted power cord with plug, the
unit cannot be installed in a wet premise! The location of the device must
comply with the requirements for the electric installation and its contact.
Refer to the electrical connection of this instruction.
It is obligatory that there are spaces provided between the appliance and the
surrounding walls and the ceiling of the premise, as follow:
џFor vertical water heaters – at least 70 mm between the appliance and
the ceiling; at least 50 mm between the appliance and the side wall; at
least 350 mm below the appliance to facilitate servicing and possible
repair .
џFor horizontal water heaters – at least 70 mm between the unit and the
ceiling; at least 70 mm between the side cover (outlets excluded) and
the wall; at least 350 mm between the electric part plastic cover and
the wall to facilitate the servicing and possible repair , and a sufficient
distance below the unit for installation of water connections and drain
the water from the tank.
џIn tanks with heat exchangers must be kept a distance from the coil
terminals side and the joints for additional thermostats necessary to
connect the additional control and safety units.
Water heater should be installed steadily on the wall of the premises. For this
purpose steel bolts (studs), tightly fixed in the wall, with diameter 10-12 mm
are used. The fixing elements should be secured against pulling aside the
wall – they should be anchor or passage bolts (depending of the wall
construction material). It is recommended that the elements on which the
heater will be suspended are designed for three times greater loads than the
appliance total weight and located in the water therein. Installation of the
water heater on decorative walls (made of single bricks or of other light
materials) is strictly forbidden. On Fig. 1,2,3,7 and in the tables are shown
the distances between the bolts (studs) for mounting the units. V ertical water
heaters of 150 liters are equipped with special type of suspension plates and
correspondingly the distance between the bolts (studs) differs from that of
other models and modifications, please refer to Fig. 1.
W ARNING! The bearing plates of horizontal water heaters must be
securely clamped to the premise wall. Under the bolts heads (nuts on
studs) must be placed support washers!
Given the greater weight for water heaters of 150 liters there are higher
requirements for fixing to the premise wall and to the wall itself:
џGiven the wall type, material and strength, in order to provide secure
attachment for vertical water heaters it is necessary to build an
additional structure or to take adequate measures to strengthen an
existing one. Samples of such constructions are shown on Fig. 15 for
reinforced concrete wall thick 25 cm and more, and on Fig. 16 - for
brick wall and others materials.
W ARNING! Non observance of the requirements for fixing the water
heater on the wall may cause damages of the appliance, damages on
other appliances and the premises, where the device is located, as well
as corrosion of the casing or even more serious failures and damages. In
such cases eventual failures and damages are not a subject to
manufacturer and seller warranty liabilities and will be at the expense of
the party which has not observed the present manual instructions.
The water heater mounting to the premise wall must be completed only by a
specialist.
W A TER HEA TER CONNECTION TO THE W A TER
SUPPL Y NETWORK
The plu mbi ng to which the wate r heat er will be conn ect ed, as well as any other
ele ments inclu ded in it sha ll hav e to w ithsta nd sus taine d wate r temp eratu res
abo ve 80°C and for short pe riods - abov e 100 °C, as well as to pr ess ure at least
twi ce high the appl iance worki ng pres sure.
Upon connection of the water heater to the water supply grid, the arrows and
indication rings around the water heater pipes for hot and cold water must be
observed (inlet and outlet pipes). With an arrow towards the pipe and blue
color is marked the cold water pipe and an arrow starting from the pipe in red
color - the hot water pipe. Some appliances pipes are additionally marked
with badges. The pipes outlets are with threading 1/2". A schematic diagram
for water heater connection is shown on Fig 8. When the water heater works
at the water pipe tank pressure and that of the safety valve. In the event
where the conduit pressure is greater than 0,5 MPa it shall be required the
ins ta ll at ion o f re duc e val ve ( pr es sur e- re du cin g va lve ). W he re lo ca l
regulations require use of additional devices that are not included with the
unit supply set and are not placed in the packaging, these must be
purchased and installed according to regulations.
The wa ter heate r is eq uippe d with a com bined non- return-s afety val ve. The
latt er is located in the p acka ging of the ap pliance and MUST OBLIGA TOR Y
be mount ed on the cold wat er pipe . During tha t insta llation the arr ow on its
hull show ing the direc tion of water flow thro ugh the valv e must be foll owed.
W ARNING ! The ab sence or imp roper insta llation of t he comb ined valve
supp lied with the produ ct is grounds for voidi ng the produ ct warran ty .
W ARNING! It is FORBIDDEN to install any kind of shut-off fittings
between the combined valve and the water heater! It is absolutely
forbidden to obstruct the lateral opening of the combined valve and/or to
block its lever!
Where the plumbing pipes are copper or of another metal, other than that of
the water tank, or where brass fasteners are used, to install on it is obligatory
the water tank inlet and outlet non-metallic couplings (dielectric fittings).
A TTEN TION! F or un its wit h hea t ex chan gers. Any a dditio nal t ubular
outl ets (excl uding tho se of the serpe ntines) that wil l b e c onnect ed with the
p l u m b i n g , a n d t h e h o l e s f o r a d d i t i o n a l t h e r m o s t a t s a n d / o r
ther momano meter must be closed with a p ackage inse rt or oth er su itable
for the purpos e. The conn ections must be sealed for a water pres sure of at
leas t 1.6 MPa.
It is recommended to set up a draining system for any dripping from the
combined valve side opening. The draining pipe must have a constant
downward slope and located in frost secure environment and its ends to be
constantly kept open to the atmosphere.
Once the water heater is connected to the water supply main, its water tank
should be filled up with water . It is carried out in the following order:
џOpen completely the turn-cock for hot water of the most distant mixing
tap.
џOpen the stop valve on pos. 4 from Fig. 8.
џWait for the air from the system to come out and over half a minute
from the fitting outlet to flow out a thick and strong water stream.
џClose the turn-cock for hot water of the mixing tap.
џlift the lever of the combined valve on pos. 5 from Fig. 8 and wait for
about 30-60 seconds until a thick and powerful stream of water runs
out from the valve side opening.
џLoose the lever of the combined valve.
W ARNING! If no water is coming out of the opening of the combined
valve or the flow is weak (during normal water pressure), this should be
considered as a malfunction indicating that impurities from the plumbing
or caused by sewage connections have blocked the safety valve of the
combined valve.
IT IS FORBIDDEN to proceed with appliance electric connection before
eliminating the reason for malfunction!
W ARNING! Failure to comply with the requirements for connection to
the water supply system may cause partial filling up of the water tank and
malfunction of the heating element, or when the combined valve is not
installed at all or has been improperly installed this may even cause
destruction of the water tank, the room and/or other damages to tangible
and intangible property . Such consequences are not within the scope of
manufacturer or seller warranty liabilities and shall be at the expense of
the party, which has not observed the present manual instructions.
W ARNING! The combined reciprocating safety valve is one of the unit
safety components ensuring security for water heater users. It is
specifically FORBIDDEN to use the water heater with a defective or
removed/unmounted combined safety valve!
The water heater connection to the water supply system must be performed
only by qualified persons.
Where necessary the safety valve may serve for draining the water out of the