Initial Operation
The device must be plugged into a properly
earthed socket.
The miniBar achieves its operating
temperature after several hours.
INSTRUCTION FOR USE
Temperature Control
The miniBar is fitted with an electronic
temperature control. The thermostat control
button is situated in the internal containers
rear area. (RH455LD, RH456LD/E: the
thermostat button is situated in the
unrefrigerated compartment).
Automatic Defrost Function
The first defrosting phase commences 39 hours after the initial operation
(5.1) and lasts for two hours.
After this, the device operates for 22 hours at a time, followed by a
defrosting period of 2 hours .
The ice layer must never be removed using
force, nor must the defrosting process ever
be accelerated using a heater.
The miniBar operates silently !
S
TT
TT
TT
S
Leakage Detection
Air sensor
The electronics carries out a leakage test after
every defrosting period ( every 24 hrs) by
measuring the temperature at the evaporator
by means of a second sensor.
If a leakage is detected, the miniBar is shut off
by the electronics.
Evaporator sensor