he gas installation should only be carried out by an
a
uthorised gas fitter.
T
he supply pipe should preferably be of copper. If any other
m
aterial is used, it must be of a type approved for use with
c
ontinuously operating bottled- gas appliances, and have
t
hreaded compression connections throughout. PUSH-ON
C
ONNECTIONS MUST NOT BE USED (We do not
a
pprove the use of "rubber" type flexible tubing for connec-
t
ing permanently operating appliances of this type in the
U
nited Kingdom). All connectors etc. should be of a type
s
pecifically designed for the type and diameter of the con-
n
ection pipe used, and screwed joints should be sealed with
a
joining compound approved for use with bottled gas.
T
he gas supply pipe should be connected to the gas inlet
p
ipe on the right hand side of the gas control valve by
m
eans of a suitable threaded compression coupling.
I
n making the connection to the refrigerator, a gas cock of
a
n approved type for use on LPG must be incorporated in
t
he supply line in a position which is readily accessible to
t
he user. For eventual servicing purposes, the union should
b
e on the outlet side of the cock and the pipework should
b
e positioned so as not to prevent the refrigerator from
b
eing readily withdrawn.
E
LECTRICAL CONNECTION
T
he electrical installation must be carried out in a proper
a
nd durable manner, taking into account all relevant regula-
t
ions and codes of practice. For mains voltage operation, it
i
s important that the circuit to and in the caravan is effec-
t
ively earthed. ALL MAINS VOLTAGE WIRING IN THE
C
ARA-VAN MUST BE INSTALLED IN ACCORDANCE
W
ITH CURRENT I.E.E. REGULATIONS INCLUDING THE
U
SE OF AN OUTLET AND COUPLER TO BS4343/-
C
EE17.
F
or connection to a 230 V electricity supply, the refrige-rator
h
as a 3-core mains lead which is intended for connection to
a
properly earthed plug and socket outlet or fused spur.
I
MPORTANT: The wires in the mains lead of this appliance
a
re coloured in accordance with the following code:
G
REEN-AND-YELLOW = EARTH
B
LUE = NEUTRAL
B
ROWN = LIVE
A
s the colours of the wires may not correspond with the
c
oloured markings identifying the terminals in your plug, in
t
he United Kingdom, proceed as follows:
T
he wire which is coloured GREEN-AND-YELLOW must be
c
onnected to the terminal in the plug which is marked with
t
he letter E or by the earth symbol
o
r coloured green or green-and-
y
ellow.
T
he wire which is coloured BLUE must be connected to the
t
erminal which is marked with the letter N or coloured black.
T
he wire which is coloured BROWN must be connected to
t
he terminal which is marked with the letter L or coloured
r
ed.
WARNING! THIS APPLIANCE MUST BE EARTHED.
I
n the United Kingdom, the plug or circuit to the refrige-rator
m
ust be fitted with a fuse not greater than 5 amps. If a 13
a
mp.(B.S.1363) fused plug is used, it should be fitted with a
3
amp. fuse. In other countries, the fuse rating will depend
u
pon the voltage and local practice.
2
30 V Supplies.
C
heck that the voltage stated on the data plate is the same
a
s the mains voltage in use (230 V).
1
2 V Supplies
C
onnect the refrigerator to the vehicle battery by a direct
c
able. To avoid a voltage drop, the cross sectional area of
t
he connecting cable between battery and refrigerator must
b
e at least 2.5 mm
2
if the distance is less than 9 meters,
a
nd at least 4 mm
2
if the distance is more than 9 meters
T
o ensure satisfactory operation, the positive lead must be
f
itted with a fuse rated at max. 16 A.
T
o prevent the refrigerator from draining the battery, make
s
ure that the current supplied to the caravan is cut off when
t
he vehicle engine is not running, for example by fitting an
i
gnition control relay.
Diagramme for the mains installation: fig. 9
Diagramme for the 12 V installation:
fig. 10 (RM 4400), fig. 12 (RM 4401)
T
he notations in the wiring diagramme are:
A. Electronic igniter/reigniter
B. Electrode (at burner)
C. 12 V heating element
D. Switch for 12 V operation
E. Switch for reigniter (gas op.)
F. Electric thermostat
G. Heating element, 230 V
H. Switch for 230 V operation
J. Terminal block
L. Terminal block
1
2 V supply of reigniter (RM 4401)
F
ig. 12 shows the wiring diagramme of the refrigerator as
d
elivered. The 12 V supply enters at (L). The reigniter (A) is
f
ed via two wires (1) and (2) at terminal block (L).
I
t is advisable to feed the reigniter and the lighting from a
s
eparate 12 V source. To do this: remove the wires (1) and
(
2) and connect the supply as is shown in fig. 11.
I
n some executions there in an extra terminal block (J), of
f
ig. 12. In this case one disconnects the wires as said above
b
ut connects the separate supply to (J).
T
he reigniter should not be connected directly to a battery
c
harger but only over a battery.
Electrical leads must be routed and secured so that
they cannot come into contact with hot or sharp parts
of the refrigerator.
12
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

electrolux-rm-4400

Suche zurücksetzen

  • Die 12 Voltlampe leuchtet nicht und die Kühlung funktioniert nicht.
    230 V und Gas funktioniert.
    Eingereicht am 6-11-2022 21:31

    Antworten Frage melden
  • Der Kühlschrank kühlt nicht mit Gas und nicht mit 230 V Eingereicht am 2-8-2020 16:40

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Electrolux RM 4400 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Electrolux RM 4400

Electrolux RM 4400 Bedienungsanleitung - Deutsch - 10 seiten

Electrolux RM 4400 Bedienungsanleitung - Holländisch - 10 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info