Page 2
3 bee ps f or a p eriod o f
3 secon ds
TEST/HUSH POWER SERVICE A LARM A LARM VENT
SENSOR VENT
Fig. 5
Testi ng A n d Resettin g Y ou r Detector
A green power light indi cates t hat power is suppl ied . T o test t he detector,
press the Test but ton. The detector will beep i ntermittentl y and the t hree
LEDs will flash. Release the Test but ton. The beep and the three LEDs will
stop and t he green LED remains on or flashes every 60 seconds .
Muti ng Y o ur Detector
You can parti all y mute the detect or in an ev ent of al arm by pressing the
Test Butt on. The Red LED wil l cont inue to f lash and a short beep wil l be
heard every 16 s econds.
Detector Mal functio nin g
A malfunctioni ng unit is indi cated by beep -soundi ng on and off
sequential ly, i.e. , beeping f or 3 seconds with 3 seconds delay between two
beeps. If this occurs, remove the batt eries f rom the unit f or 10 seconds
and then i nstall them again. Should t he unit again beep i ntermittentl y, DO
NOT use thi s detect or. Send the malfuncti oning uni t to t he manufacturer
for servi cing.
Taki ng Care Of Y ou r Detector
You have to maintai n the detec tor to ens ure proper operation:
1. Use a vacuum cleaner to cl ean the air vents oc casional ly to keep
them free of dust.
2. Press t he Test but ton on y our detector t o test its operati on once
every week.
A ctions to T ake When A l arm S ound ing
In case of harmful lev els of CO gas being detected, your detector will go
into a c ontinuous full alarm. Try to take the fol lowing necessary acti ons
immediately:
(a) If ther e is an yon e e xp er ienc ing the effe cts of c arb on m ono x ide
pois onin g s uch as hea dac he, dizz iness , na use a o r o the r flu -like
sym pt om s, c all yo ur fire de par tm en t o r e me rg enc y se rvice de par tm en t
righ t a w ay. Y ou sho uld eva cua te a ll th e p eop le in the pr em ise s
im m edia tely. Do a hea d c oun t to che ck t hat eve ryb ody is p res ent .
(b) Do not re-enter t he premises unti l t he problem has been correc ted
and the CO gas has been dis persed out and a safe l evel i s reached.
(c) If no s ymptom s exist, immediately venti late th e home by opening
window s and doors. Turn off fuel burning appl iances and call a
qualif ied tec hnici an or your uti li ty c ompany to inspect and repair y our
problem before restarti ng appli ances.
WARNI NG: Norm all y an act ivati on of t he detector i ndicat es the pre senc e
of CO gas. However, the CO gas can be extremely fatal , i f it is not
detected. T he source of the CO gas may come from several possibl e
situat ions, please ref er to the l ist of sourc es of c arbon monox ide i n page 1.
CAUTI ON: This det ector will only indi cat e the presence of CO gas at the
sensor. However, you hav e to be aware that the CO gas may be present i n
other areas i n the premises.
A ctions to T ake A fter T he P robl em is Corrected
Once the probl em of the CO gas presence i n the premises has been
corrected, the detect or alarm shoul d be off. After waiti ng for 10 minutes,
push the Tes t button to test the detect or, and by that , being confident that
the detector is working properly agai n.
Tech nical Info rmation
The Carbon Monoxide Detector is engineered t o be ab le to provide al arm
sounds based on the UL standards due to vari ous exposure times at
different level of c arbon monox ide concent rations.
According to the Underwriters Laborat ories I nc. the carbon monoxide
concentrati ons and exposure ti me standards for the al arms have been
establi shed and specif ied bel ow:
A full alarm is acti vated under the foll owing conditi ons:
- between 60 and 90 minutes at exposures of 70 ppm
- between 10 and 30 minutes at exposures of 150 ppm
- between 4 and 10 minutes at exposures of 400 ppm
2 x CR 123 , 3V Lith ium Battery
20 A standby, 3 0mA Alarm
Supe rvision Transmissio n:
15 min. - fo r 868.6 5 MHz model
65 min. - f or 43 3.92 MHz model
85 dB at a dista nce of 3 meters (10 fe et)
140 X 80 X 49 mm
(5.5 inch x 3.2 inch x 2 inch )
4 C to 38 C (39 F to 1 00 F)
-20 C to 60 C (-4 F to 14 0 F)
Based on th e requ irements o f UL 20 34 Stan dard
Specif ica tions are subje ct to chan ge with out prio r notice. Sh ould any qu estion s
arise ple ase co ntact you r suppli er.
WARNI NG A ND L IMIT A T ION
Th i s d e t e c t o r m a y n o t a l a r m a t l o w c a rbo n m o n o xi d e l e v e l s . Th e
Oc c u p a ti o n al S a f e t y a nd H e a l t h A s s o c i a t i o n ( O S H A ) h a s e s t a b l i s h e d t h a t
co nt i n u o u s e xp o su r e l e v e l s o f 3 0 p p m s h o u l d n o t b e e x c e e de d i n a n 8
h o u r s p e r i o d . In d i v i d u al s w i t h a me d ic a l p r o b l e m m a y co ns i d e r m o r e
se ns i t i v e d e t e c t i o n d e vi ce s.
Th e C O g a s d e t e c t o r i s n o t s u i t a b l e a s a s mo ke o r f ir e d e t e c t o r . Th is
d e t e c t o r i s n o t s u i t a b l e t o i n s t a l l i n a h a z a r d o u s l o c a t i o n , a s d e f i n e d i n t h e
N a t io n a l E l e ct r i ca l C o d e .
Th i s d e t e c t o r w i l l n o t w o r k w i th ou t p o w e r . E L ' s C a r b o n Mo n o x i d e D e t e c t o r
wil l n o t w o r k i f th e b a t t e r i e s a r e re mo v e d f o r a ny r e a s o n . A d d i t i o n a ll y ,
ca rb o n m o n o x i d e m u s t re a ch t h e d e te c t o r f o r t h e p r o p e r p e r f o rm a n c e o f
C O g a s d e t e c t i o n .
C a rb on m o n o xi d e d e te c t o r s ma y w e a r o u t b e c a u se t h e y c o n t a i n e l e c t r o n i c
p a r t s t h a t f a i l a t a n y t i m e. T e s t y o u r d e t e c t o r a t le a st o n c e w e e k ( s e e t h e
se ct i o n " TE S T IN G Y OU R D E T E C TO R " ).
Electro nics L ine Ltd.L imi ted Warranty
EL a nd i t s s u bs id i ar i es and affi li a te s ( " S el l er " ) war r an t s it s p ro du c ts t o b e fr e e fr o m
de fec t s i n m a t er i al s a nd wo r km a ns h ip un de r n or m al us e fo r 2 4 m o nt hs fr om t h e da te o f
pr o du ct i on . Bec a us e Sel l er do es no t ins t a ll or c on ne ct t he pr od uc t and bec au se th e
pr o du ct m a y be u se d in c o nj un c ti o n w it h pr od uc t s no t m a nu fac t ur e d b y t h e S el l er ,
Se l le r c an n ot guar a nt e e t h e per fo r ma nc e o f t h e se c uri t y s y s t em whi c h us es thi s
pr o du ct . S el l er s ' ob l ig at i on an d l i ab il i ty un de r t h is w ar r an t y i s e xp r es s ly l im i t ed t o
r ep ai r in g an d re pl a ci n g, at Se l le r s o p ti o n, wi th i n a re as on ab l e ti m e aft er the d a te o f
de li v er y , an y pr o du ct not mee t in g th e spe c ifi c at i on s . Sel le r m ak e s no ot he r wa r r an ty ,
ex pr e s se d or im pl i ed , and mak e s no war r a nt y of me r ch an t ab il i t y or of fit n es s for any
pa r ti c ul a r pu r po se . I n no ca s e sha l l sel l er be lia bl e for any con s eq ue nt i al or in c id en t al
da m ag es for br e ac h of th i s or any ot he r war r a nt y , ex pr es s ed or im pl i ed , or up on any
ot he r b as is o f l i ab il i ty w h at s oe ve r . S e ll er s o bl i ga ti o n u nd er t h is w ar r a nt y s ha ll n ot
in c lu de any t r a ns p or t at i on c h ar g es or co s ts of in st a ll a ti o n or any li a bi l it y for dir e c t,
in di r ec t , or n ot be co m pr o m is ed or c i r cu m ve nt e d; th at th e pr o du c t w il l pr ev en t any
pe r so na ; i nj u ry or pro pe r t y los s b y i nt r u de r, rob be r y, fir e or oth er w i se ; o r t h at th e
pr o du ct wi l l in all ca se s pro v id e ad eq ua te wa rn i ng o r p r ot ec t i on . B uy e r und er s t an ds
t hat a pr op er l y in st a ll ed and ma in t ai ne d al ar m m a y onl y r e du ce t h e ri s k of int r ud er ,
r ob be ry or fir e w it h ou t war n in g, bu t is no t ins ur a nc e o r a gua r ant y th at su ch wi ll not
oc c ur o r t ha t th er e wi ll be no p er s on al in j ur y or pr op er t y lo ss as a r es ul t . Co ns eq ue nt l y
se l le r s ha l l ha ve n o li a bi l it y fo r a ny p er s on al i n ju r y, pr op er t y d am a ge o r l os s ba s ed o n a
cl a im t ha t th e pr o du c t fail s to gi ve wa r ni ng . Ho we v er , if s el le r is hel d li ab l e, whe t he r
di r ec t l y or ind i r ec t ly , for any los s or da m ag e ar is i ng fro m un de r t hi s l im i t ed war r an t y or
ot he r w is e , r eg ar dl e ss of cau se or ori g in , se l le r s m ax i mu m li ab il i ty sh al l not exc e ed t he
pu r ch as e pr i c e of the pr o du ct , wh i ch sh al l be co m pl et e and ex c lu s iv e re m edy aga in s t
se l le r . No em p lo y ee or r ep r es e nt at i v e o f Se l le r is aut h or i z ed to cha ng e t hi s wa r ra nt y in
an y w ay or g r an t a ny ot he r w a r ra nt y .
WA RN IN G: This prod uct shou ld be tested a t least on ce a we ek.
CA UTION : Risk of explosio n if battery is re place d by a n incorrect type. Dispose
of used batterie s accordin g to lo cal regu lation s.
Contacti ng E lectron ics Li ne L td.
Internatio nal H eadquarter s:
Electronics Line Ltd.
14 Ha choma St., 75 655
Rishon Le Zion , Israel
Tel: (+972 -3) 963 -7777
Fax: (+972 -3) 961 -6584
All rights rese rved.
No pa rt of th is docu ment may be reprod uced in any f orm with out prio r written
permission fro m the pu blishe r.
(CE is for 86 8.65 MHz model on ly )
© Electronics L ine L td. 02 /11 5IN1488