658065
12
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
SK 200 SK 230 SK 260 SB 200 SB 230 SB 260
Mains voltage 220 - 240 V 220 - 240 V 220 - 240 V 220 - 240 V 220 - 240 V 220 - 240 V
380 - 415 V 380 - 415 V 380 - 415 V 380 - 415 V 380 - 415 V 380 - 415 V
Mains frequency 50 H 50 Hz 50Hz 50Hz 50Hz 50 Hz
Welding steps stepless stepless stepless stepless stepless stepless
Current Range 25-200 A 25-230 A 25-260 A 20-200 A 20-230 A 30-260 A
Stepless at 220/240 V 25-110 A 25-114 A 25-120 A 20-110 A 20-114 A 30-135 A
Stepless at 380/415 V 40-200 A 40-230 A 40-260 A 30-200 A 36-230 A 75-260 A
Max. OCV
at 220 - 240 V 36.5 - 39 V 37.0 - 40 V 36.0 - 40 V 36.5 - 39 V 37.0 - 40 V 39.0 - 40 V
Max. OCV at 380 - 415 V 48.5 - 55 V 53.0 - 59 V 55 - 60 V 48.5 - 55 V 53.0 - 59 V 55.0 - 60 V
Max. input cap. at 220 - 240 V 4.3 kVA 4.5 kVA 4.4 kVA 4.3 kVA 4.5 kVA 4.5 kVA
Max. input cap. at 380 - 415 V 11.8 kVA 13.7 kVA 16.4 kVA 11.8 kVA 13.7 kVA 16.4 kVA
Working voltage 21.0-28.0 V 21.0-28.8 V 21.0-30.2 V 21.0-28.0 V 21.0-28.8 V 21.0-30.2 V
Cos - 220 - 240 V 0.77 (110 A) 0.77 (114 A) 0.80 (120 A) 0.77 (110 A) 0.77 (114 A) 0.8 (130 A)
Cos - 380 - 415 V 0.66 (200 A) 0.63 (220 A) 0.62 (260 A) 0.67 (200 A) 0.63 (220 A) 0.62 (260 A)
Duty cycle at max.
output 220 - 240 V* (25 / 40°) 25 %/ 17 % 25 %/ 17% 25 %/ 17% 20 %/ 15 % 55 %/ 40 % 50 %/ 35 %
100% duty cycle 220 - 240 V*
(25 / 40°) 55 A/ 35 A 60 A/ 40 A 55 A/ 35 A 50 A/ 35 A 85 A/ 60 A 90 A/ 65 A
Duty cycle at max.
output 380 - 415 V* (25 / 40°) 5 %/ 3 % 5 %/ 3 % 5 %/ 3 % 5 %/ 3 % 20 %/ 15 % 10 %/ 1,5 %
100% duty cycle 380 - 415 V*
(25 / 40°) - - - - - 90 A
Mains fuse 220 - 240 V 16 A time-lag 16 A time-lag 16 A time-lag 16 A time-lag 16 A time-lag 16 A time-lag
Mains fuse 380 - 415 V 25 A time-lag 25 A time-lag 35 A time-lag 20 A time-lag 25 A time-lag 35 A time-lag
Cooling self self self self fan fan
Insulation class F F FFFF
Protection class IP 21 IP 21 IP 21 IP 21 IP 21 IP 23
Dimensions (lxwxh) in mm 440x230x430 440x230x430 440x230x430 550x330x380 550x330x380 550x330x380
Weight 27 kg 31 kg 35 kg 40 kg 44 kg 44 kg
Accessory kit no. 7 8 8 130 8 8
Max. electrode diameter 5 mm 5 mm 5 mm 5 mm 5 mm 5 mm
2.1 Putting A combination 1-Ph/2-Ph Machine Into Operation
All "Combi" machines are supplied with a plug (CEE 5 pin 16/32 A) installed on the power cable. Connect to a 220 - 240 V
single-phase outlet with the adaptor supplied or to two phases of a 380/415 V 3-phase mains.
1.0 Specifications
- This welding machine should be connected to the power source via an Earth Fault Circuit Interrupter with 30 mA
capacity.
- Have worn or damaged power cables replaced immediately by a qualified electrician.
Do not operate the welding machine with a damaged power cable, danger of personal injury through electric shock.
- Children under the age of 16 should not operate this welding machine.
Connect to an earthed, single-phase 220 - 240 V outlet on a circuit protected by a 16 A time-lag fuse. Double insulated
machines (with PVC housing) do not require an earthed outlet. Operating other electrical machines or appliances on
the same circuit while welding is not recommended.
If your machine has detachable welding and earth cables, connect cables to the sockets, lock by turning plug clockwise.
With transformers the polarity does not matter, so both cables can be connected to either the + or - sockets. The same
applies for machines with permanently attached earth and welding cables.
Attach earth clamp to the work piece, close to the area to be welded and on to bare metal for good conduction. Place
a stick electrode into the electrode holder.
Set current selector switch to desired current. On all machines with stepless setting turn crank or handwheel until
desired current is indicated (stepless).
If there is no power outlet near the work piece an extension cable is required. The cable lead cross section must be
at least 2.5 mm
2
. The extension cable should be fully uncoiled to prevent heat build-up by inductance. Inductance also
considerably reduces the welding current. Extending the welding cables is also possible, however the cross section
of the extension cable should be larger than that of the cable supplied with the machine. Every machine is overload
protected by a thermo switch, which switches the transformer off if it becomes too hot. Let cool down until machine
switches on automatically. Some machines are equipped with a fan to increase the duty cycle through forced cooling.
The fan operates as long as the machine is switched on.
2.0 Putting A Single-Phase Machine Into Operation
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elektra Beckum SB230 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info