820604
8
Zoom out
Zoom in
Vorherige Seite
1/22
Nächste Seite
8
Chapter 6
INSTALLATION MANUAL |
7 INSTALLATION METHOD
In all Element4 replaces, a free space of 100mm at least 50mm
must be maintained immediately above and below the main housing
for good air circulation. (Failure to do so may cause problems for the
heating and ame function).
Each Element4 replace is supplied with one or more wall mounting
brackets.
Determine the height at which the nished Element4 replace should
be positioned in relation to the oor level.
Note: The minimum distance to the oor is 300 mm
Attach the wall bracket to the wall, making sure that you use the correct
fasteners that match the respective wall - hollow or solid.
Hang the Element4 replace on the bracket and secure it in place with
the wall bracket at the top of the replace.
Insert the plug of the IEC-compliant power cable into the IEC-compliant
socket and ensure that it is rmly pushed.
Construct the hollow installation space for the electric re in the
desired dimensions. It is important that you take into account the
nished front when determining the depth of the frame construction.
It is important that a header/lintel is also placed at the desired height,
so that the weight of the wall made will not come to rest on the
appliance.
Make the cut in the plasterboard / nishing plate and install the
replace, making sure that the plaster board edges connect to the
inside of the cut in the plate.
Warning: In order to avoid a hazard due to inadvertent resetting of
the thermal cut-out, this appliance must not be supplied through an
external switching device, such as a timer, or connected to a circuit
that is regularly switched on and o by the utility.
7�1 PRODUCT SIZE
Theproduct dimensions can be found in APPENDIX BAPPENDIX B
It is also important to ensure that the product has a minimum clearance
around it of 15mm, this is to ensure that the product can circulate the
required airow to the heater unit.
The product should never be sealed into an opening with the use
of silicones or adhesives as this can alter the airow and hinder any
further servicing of the product.
Please refer to technical specication table for further information, with
reference to measurements.
6 INSTALLATION REQUIREMENTS
This product has been designed to be installed into a plaster board, or
existing masonry chimney breast.
Please seek advice from a professional, with reference to the structural
integrity of the installation site.
If the product is to be installed into a open chimney or ue, it is
important that the chimney/ue is blocked o to prevent any up/down
draughts and falling debris which could restrict and alter the airow to
the product.
It is also important to ensure that the product has a minimum internal
clearance directly above and below the product of 100mm, this is to
ensure that the product can circulate the required airow for the heater
unit.
The product should never be sealed into a opening with the use of
silicones or adhesives as this can also alter the airow and hinder any
further servicing of the product.
6�1 HEATER UNIT CUT OUT
This is a safety feature to safe guard against further damage to the
product.
If the airow is restricted the heater will automatically turn o. This can
occur due to incorrect installation or obstruction. To reset the heater
function;
Isolate from main power supply
Leave product to cool
After suitable cooling down period, remove the obstruction if
obstructed and check installation
After 10 minutes the thermo switch (cut-out) in the heater will
reset.
Please note: that both the eect fan and heater fan omit a low decibel
noise, both of which are normal operating characteristics.
6�2 SERVICING
Only a competent person should service this appliance. This appliance
must be serviced every 12 months.
Warning: Before carrying out any repairs or servicing, ensure that the
power supply cord is removed from the mains supply.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Element4 Ambiance-E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Element4 Ambiance-E

Element4 Ambiance-E Installationsanweisung - Deutsch - 22 seiten

Element4 Ambiance-E Installationsanweisung - Holländisch - 22 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info