INSTALLATION MANUAL
5 INSTALLATION PREPARATION AND - INSTRUCTION
The device is developed, tested and approved conform the
applicable standards for the usage, the performance and safety
of the product. The installation of your device must apply to
the current building prescriptions. We advise to make use of
a qualified gas installer for the installation of your device. The
installer can provide you with all information regarding the
safety regulations of the installation.
5.1 Relevant norms and guidelines
The installation must be carried out in accordance with the
following regulations
Department of the Environment, the Building Standards
(Scotland) (Consolidation) Regulations issued by the
Scottish Development Department.
BS 5440 part 1
BS 5871 part 2
BS 6891.
In the Republic of Ireland the installation must also conform to
the relevant standards, particularly in regard to flue sizing and
ventilation. Refer to documents;
IS813
ICP3
IS327
Any other rules in force.
This appliance must be installed in accordance with the rules
in force and used only in a su iciently ventilated space, and is
intended for use on a gas installation with a governed meter.
5.2 Attention points gas fireplace
This device can be place in a new or existing situation. The device
can be installed in a fully enclosed or mechanically ventilated
room without extra ventilation.
Before installation of these appliances, the area into which the
fire is to be fitted must be cleared of all debris (including dust), in
particular combustible material.
5.3 Attention points gas connection
The gas connection should apply to the local norms in force.
Calculate the diamater of the gas flue, such that no pressure loss
is occuring in the pipes. Place a shut-o valve in the near vicinity
of the device. Position the gas connection, such that it is always
accessible for service purposes.
Put the gas block and receiver behind the included service hatch.
Make sure that it is always accessible for service purposes. (See
Figure 5-1)
5.4 Requirements flue and wall terminals
The European CE-marking for the device is only applicable to
the flue materials specified by the supplier. The device must be
installed with the stainless steel flue material US by Metaloterm/
On top. The usage of other stainless steel material is only
permitted when it has the same technical specification as the
previous mentioned systems.
Only when these materials are used a good and safe performance
can be promised by Element4.
The flue channel works as a roof terminal (B11), as well as flex
pipes in an existing channel.
Please check, whether the desired terminal complies with the
regulation for your situation (See:
APPENDIX D).
It is possible that an extra shield is necessary when the terminal
is within two meters from the ground.
5.5 The chimney
Before the chimney is installed, we advice an operation test
with the device. The chimney should be constructed from non-
combustible materials and cannot rest on the mounting frame.
Always use a chimney iron, when using bricks or cell concrete.
The chimney ventilation should meet the the local norms. A well
ventilated chimney makes sure the temperature is regulated to
ensure a proper operation of the electronics and the gasblock.
Furthermore, good ventilation helps to keep the convection air
under 85
o
C.
More on chimney construction in THE NEXT CHAPTER.
Figure 5.1 - Service Hatch (BDLE4)
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Element4 Cupido 60 CF wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Element4 Cupido 60 CF

Element4 Cupido 60 CF Bedienungsanleitung - Deutsch, Englisch - 56 seiten

Element4 Cupido 60 CF Installationsanweisung - Holländisch - 36 seiten

Element4 Cupido 60 CF Bedienungsanleitung - Holländisch, Französisch - 56 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info