CARATTERISTICHE TECNICHE
Tensione nominale di alimentazione: ........ 12V +/- 3V
Assorbimento a 12 V : ..................... ....... 8m A no m. 22mA max
Sensibilità Microonda (MW): ........... .......... 0,5÷ 15m± 20% (con tri mmer)
Frequenza: ....................................... ......... 10,525 GHz
Potenza di emissione (EIRP): ........... ......... 8dBm
Portata: ..................... ...................... ........... 15 m
Copertura MW: .......................... ................ 90° orizzontale - 36° verticale
Copertura IR: ........... ...................... ............ 90°
Zone sensibili: ................................... ........ 18 su 4 piani con creep zone
Opto Relè di allarme: .......................... ....... 100m A / 24V
Tamper antimanomissione: ....................... 100 m A / 30V
Tempo Allarme: ........................ ................ 3 sec
Temperatura di funzionamento: ........ ......... -10°C ÷ +55°C
Umidita Ambientale:......................... .......... 95%
MTBF Teorico: ....... ...................... .............. 120.000 ORE
Dimensioni (h x l x p): ..................... ........... 107x61,5x43,5 mm
Peso: ............... ...................... .................... 110 g
Livello Prestazione: ......................... .......... EN50131-2-4. Grado 2, CLASSE II
ACCESSORI OPZIONALI
• Snodi per IR15 - DT15 - DT15AM (10 pezzi) ref. 80SP1E00113 / ref.
80SP1F00113
AVVERTENZE
• Installare il senso re su superfici rigide, prive di vibrazioni, ad una altezza
compresa tra 2 e 2,3 metri facen do riferimento ai diagrammi di rileva zione in
modo tal e che il sensore rilevi spostamenti trasversali nella zona protetta.
Evitare il posizionamento del sensore vicino a fonti di calore o alla luce diretta
del sole.
• Evitare la rifle ssione dell’energia el ettromagnetica su ampie supe rfici quali ad
esempio specchi, pareti metalliche etc.
• Evitare di puntare il senso re su lampade fluorescenti o comunque di porlo nelle
immediate vicinanze delle stesse.
• Evitare che es istano, a causa di m obili , scaffalature, etc. zone c ieche nell’area
protetta entro cui possa m u oversi l’intruso. Evita re la presenza d i animali
nell’area protetta.
• Nel ca so di installazioni ad altezze sup eriori a i 2,1 m e tri si consiglia l ’utilizzo
dello snodo opzionale, i nclinando il sensore in modo d a a dattare a l m egl io i
campi di copertura alle effettive necessità.
INSTALLAZIONE SENZA SNODO
Per rimuovere il coperchio del sensore togliere la vite di chiusura (se i nserita) e
premere con un cacciavite sul dente di fissaggio, verso l’interno della feritoia.
Per togliere il circuito stampato allargare uno dei ganci E1-E2 (Fig. 2).
Attenzione: non toccare con le dita il sensore piroelettrico.
Fondo plastico del sensore (Fig. 2):
F1-F4 = PREDISPOSIZIONI PER IL FISSAGGIO AD ANGOLO
A-B = PREDISPOSIZIONI PER IL FISSAGGIO SU SUPERFICIE PIANA
C-D = PREDISPOSIZIONI PER IL PASSAGGIO CAVI
Fissare il fondo plastico a lla parete con le v iti e i tasselli, avendo cura che le teste
delle stesse n on tocchino l a scheda e lettronica. Rimontare i l c ir cuito su l fondo
plastico.
INSTALLAZIONE CON SNODO
I manuali completi degli snodi sono disponibili sul sito www.elkron.com.
DESCRIZIONE MORSETTIERA
I Ingresso Inhibit
- + Alimentazione 12V
NC TAMP Contatto N.C.
NC ALL Contatto N.C. del relè di allarme
PRIMA ALIMENTAZIONE
Fornita l’alimentazione, il sensore entr a nella fase di inizializzazione, durante la
quale i 3 LED lampeggiano alternativamente. Dopo questa fase ( che dura 60
secondi circa), il sensore diventa operativo.
In questa modalità, indipendentemente dallo stato del Jumper d i LED OFF, il
sensore visualizzerà le rilevazioni della Microonda, quelle dell’Infrarosso e lo
stato di Allarme per permettere all’Installatore di verificarne il funzionamento.
Questa condizione permane per 20 minuti.
Trascorso questo tempo il Sensore visualizzerà:
se in Led ON ( Jumper inserito) solo gli Allarmi tramite il led Blu;
se in Led OFF (Jumper NON inserito) solo eventuali memorie.
Procedere con il walk test in questo modo:
MW (Microonda)
Regolare il trimmer (portat a 0, 5 - 15 mt) i n fun zio ne dell’ambiente da pr oteggere,
verificando le rilevazioni di MW tramite il LED VERDE.
Nota: la por tata della MW va regolat a al minimo necessario poiché, esse ndo le
Microonde in g rado d i oltrepassare i muri, po ssono rilevare disturbi e m ovimenti
all’esterno del locale da proteggere.
INFRAROSSO (PIR)
Applicare il frontale plastico e, a LED spenti, m uoversi nell’area di pertinenza del
sensore verificando la rilevazione del PIR tramite il LED GIALLO.
FUNZIONI
AUTOMATIC ECO
Il sensore è eq uipaggiato con uno speciale algoritmo che riduce al mini mo le
emissioni della Microonda.
Senza necessa riamente collegare l’ing resso di Inh ibit, il sensore, tram ite il
monitoraggio dei movim enti nell’ambiente, determina se l’im pi anto è inserito o
disinserito.
Questa co gnizione gli p ermette di li mitare al massi mo le e missioni di Microonda
ad im pia nto disinserito e quindi d i non irradiare i nutilmente l e pe rsone presenti
nell’ambiente.
Si ottiene questo vantaggio p ur senza avere ne ssuna perdi ta di sensibilità di
rilevazione, né di immunità ai falsi allarmi.
LED OFF - Jumper Disinserito (di fabbrica inserito)
Disattiva l e visualizzazioni di rilevazione, mantenendo abilitate le vi sualizzazioni
relative alle memorie.
FUNZIONI CON INGRESSO INHIBIT
Queste funzioni vengono attivate/disattivate tram ite inserimento/disinserimento
dell’impianto. A tale proposito viene considerato:
• 12V sull’ingresso INHIBIT = impianto disinserito
• 0V sull’ ingresso INHIBIT = impianto inserito
ABILITAZIONE REMOTA LED - CONDIZIONE RICHIESTA LED OFF
Al disinserimento d ell’impianto, il sensore si predispone a lla riabilitazione delle
visualizzazioni di rilevazione. Le visuali zzazioni verranno riabilitate alla prima
rilevazione effettuata e rimarranno attive per 30sec.
MEMORIE
Al disinseri mento d ell’impianto, verrà visu alizzata la memoria del primo allar me
avvenuto, com e in TAB.1 (VISUALIZZAZIONI IN STATO DI MEMORIA). La
memoria verrà resettata al successivo inserimento dell’impianto.
RITARDO della MEMORIA per utilizzo in INGRESSI TEMPORIZZATI
Tempo di u scita: gli allar mi che si verificano entro i primi 30 ” dall’inserimento
dell’impianto vengono cancellati.
Tempo di ingresso: gli allarmi che si verificano 3 0” prima del disinserimento
dell’impianto vengono cancellati.
DICHIARAZIONE DI CONFORMITÀ UE SEMPLIFICATA
Il fabbricante, URMET S.p.A., dichiara che il tipo di apparecchiatura radio:
RIVELATORE A DOPPIA T ECNOLOGIA DT15 è conforme alla direttiva
2014/53/UE. Il testo completo della dichiarazione di conformità UE è disponibile
al seguente indirizzo Internet: www.elkron.com .
DIRETTIVA 2 012/19/UE DEL P ARLAMENTO EUROPEO E DEL
CONSIGLIO d el 4 luglio 2012 sui rifiuti d i a pparecchiature elettriche
ed elettroniche (RAEE).
Il simbolo del cassonetto barrato riportato sull’apparecchiatura o su l la sua
confezione indica che il prodot to alla fine della propria vita utile deve essere
raccolto s epar atam ente dagli altri ri fiuti. L’utente dovrà, p ertanto, conferire
l’apparecchiatura giunta a fine vita agli i donei centri comunali di r accolta
differenziata dei r ifiuti e lettrotecnici ed elettronici. I n a lt ernativa alla gestione
autonoma è possibile consegnare l’apparecchiatura che si desi dera smaltire al
rivenditore, al momento dell ’acquisto di una nuova apparecchiatura di tipo
equivalente. Presso i rive nditori di prodotti elettronici con superficie di ve ndita di
almeno 4 00 m 2 è inol tre poss i bile consegnare gratuitamente, senza obbligo di
acquisto, i prodotti elettronici da sm alti re con dimensione m assi ma inferiore a 25
cm. L’adeguata raccolta differenziata per l ’avvio successivo dell’apparecchiatura
dismessa al riciclaggio, al trattamento e all o smaltim ento a mbientalmente
compatibile contribui sce ad evitare poss ibili effetti nega ti vi sull’ambiente e su lla
salute e favorisce il reim pi ego e/o riciclo dei materiali di cui è composta
l’apparecchiatura
.
TECHNICAL SPECIFICATIONS
Nominal power voltage: ............... .............. 12V +/- 3V
Consumption at 12 V :
.......................... 8mA nom.
22mA max.
Microwave sensitivity (MW):
.......... .......... 0,5÷15m± 20% (with t rimmer)
Frequency: ...... ...................... .................... 10.525 GHz
Emission power (EIRP): ........... ................. 8dBm
Range: ..................... ...................... ............ 15 m
MW coverage: ... ...................... .................. 90° horizo ntal - 36° vertical
IR coverage: ..... ...................... ................... 90°
Sensitive zones:
..... ...................... ........... 18 on 4 floors with creep zone
Alarm relay opto: ........................ ............... 100mA / 24V
Tamperproof switch: .................... .............. 100 mA / 30V
Alarm time:
..... ...................... ................... 3 sec
Working temperature range: .............. ........ -10° C – +55° C
Ambient humidity: ... ...................... ............. 95%
Theoretical MTBF: . ...................... .............. 120,000 HOURS
Dimensions (h x w x d): ................ ............. 107x61.5x43.5 mm
Weight: ............... ...................... ................. 110 g
Performance level: ............... ..................... EN50131-2-4. Degree 2, CLASS II
OPTIONAL ACCESSORIES
• Brackets for IR1 5 - DT15 - DT15AM (10 pcs) Ref.
80SP1E00113 / Ref.
80SP1F00113
CAUTIONS
• Install the sensor on rigid, vibration-free surfaces at a height comprised
between 2 and 2.3 metres m aking reference to the detect ion diagrams so that
the sen sor can detect movements crossi ng the protected zone and the
microwave m odul e can detect approaching movem ents.
Avoid positioning the
sensor close to sources of heat or direct sunlight.
• Avoid th e reflection of electromagnetic energy on large s urfaces, such as
mirrors, metal walls etc.
• Avoid pointing the senso r tow ards, or in al l cases p lacing it n ear, fluorescent
lights.
• Avoid the creation of blind a reas caused by fur niture, shelving et c. i n the
protected ar ea in which a n intruder co uld move about .
Avoid the presence of
animals in the protected area.
• In case of installations at heights greater than 2.1 metres, it is advisable to use
the op tional bracket, i ncluding the sensor so as to adapt the co verage fields
better to the actual needs.
INSTALLATION WITHOUT BRACKET
To r emove the senso r cover, remove the fasteni ng screw ( if inserted) and press
with a screwdriver on the fastening screw towards the inside of the slot.
Widen one of the hooks E1-E2 to remove the printed circuit (Fig. 2).
Warning:
do not touch the pyroelectric sensor with your fingers.
Plastic bottom of the sensor (Fig. 2):
F1-F4 = SET-UP FOR FIXING IN CORNER
A-B = SET-UP FOR FIXING ON FLAT SURFACE
C-D = SET-UP FOR CABLE PASSING
Fix the pl astic bottom to the wall with screws and anchor b olts being careful that
they do not touch the electronic board.
Refit the circuit onto the plastic bottom.
INSTALLATION WITH BRACKET
The complete u ser m anual s of t he brackets are available on the website
www.elkron.com.
TERMINAL BOARD DESCRIPTION
I
Inhibit input
- + 12V power
NC TAMP
NC contact
NC ALL
NC alarm relay contact
FIRST POWER-ON
When power i s con nected, the sensor w ill start an i nitialising ste p during w hich
the three LEDs w ill blink a lternatively.
The sen sor will sta rt working after th i s step
(which lasts approximately 60 seconds).
In th is mode, regardle ss of the state of the LED OFF jumper, the sensor will show
the microwave detections, the infrared detection and the alarm state to allow the
installer to check operation.
This condition will persist for 20 minutes.
The following will appear on the sensor after this time:
in LED ON mode (jumper on) alarms only by means of the blu e LED;
in LED OFF mode (jumper NOT inserted) memories onl y.
Proceed with the walk test, as follows:
MW (Microwave)
Set the trimmer (range 0.5 - 15 m) according to the environment to be protected
and check the MW detections by means of the GREEN LED.
Note:
The MW range mu st be set to th e mi nimum because microwaves can cross
walls and detect disturbances and movements outside the room to be protected..
INFRARED (PIR)
Apply the plastic front and with the LEDs off m ove in the area of pe rtinence of th e
sensor checking PIR detection using the YELLOW LED.
FUNCTIONS
AUTOMATIC ECO
The sensor is provided with a special algorithm which r educes to the microwave
emissions to the minimum.
Without needing to connect th e Inhibit i nput, the sensor determines whether the
system is on or off by monitoring the movements in the environment.
This allows to limit microwave emissions to the mini mum when the system is off
and to avoid unnecessary radiations for the people present in the environment.
This advantage i s achieved without losing detection sensitivity or false ala rm
immunity.
LED OFF - Jumper off (on by default)
Deactivates the detection views maintaining the memory views enabled.
FUNCTIONS WITH INHIBIT INPUT
These functions are activated/deactivated by switching the system on and o ff.
With this regard:
• 12V on the INHIBIT input = system off
• 0V on the INHIBIT input = system on
REMOTE LED ENABLING - LED OFF REQUIRED CONDITION
The sensor i s set to re-enable dete cted views when the syst em i s switched off.
The views will be re-enabled at the first detection an d will remain active for 30s ec.
MEMORIES
The memory of the first alarm will be viewed when th e system is switched off as
shown i n TAB . 1 (MEMORY ST ATE V IEWS).
The m emory w il l be reset when
the system is switched on again.
MEMORY DELAY FOR TIMED ENTRANCE
Exit time:
the alarms occurrin g during th e first 30" from when the system is
switched on are deleted.
Entrance ti me:
the alarms occur ring during t he 3 0" before th e syste m is sw it ched
off are deleted.
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment type: DUAL
TECHNOLOGY DETECTOR DT15 is in compliance with Directive 2014/53/EU.
The full te xt of the EU declaration of co nform ity is available a t the following
internet address: www.elkron.com .
DIRECTIVE 2012/19/ EU OF THE EUROPEAN PARLIAMENT A ND O F
THE COUNCIL o f 4 July 2012 o n waste e lectrical and electronic
equipment (WEEE).
The symbol of the crossed-out wheeled bin on the product or on its
packaging indicates that this product must not be disposed of with your other
household waste.
Instead, it is your responsibility to dispose of your waste equipment by handing
it over to a designated collection point for the recycling of waste electrical and
electronic equipment. The separate collection and recycling of your waste
equipment at the time of disposal will help to conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment.
For more information about where you can drop off your waste equipment for
recycling, please contact your local city office, your household waste disposal
service or the shop where you purchased the product.
CARACTERISTIQUES TECHNIQUES
Tension nominale d’alimentation :.............. 12V +/- 3V
Absorption à 12 V : ..... ...................... ..... 8mA no m. 22mA maximum
Sensibilité micro-onde (MW) : ................... 0,5÷ 15m±20% (par
commutateur)
Fréquence : ....... ...................... ................... 10,525 GHz
Puissance d'émission (EIRP) : ......... .......... 8 dBm
Portée : ...... ...................... ...................... .... 15 m
Couverture MW : ................... ..................... 90° horizontale - 36° verticale
Couverture IR :..................... ...................... 90°
Zones de détection : ................................. 18 faisceaux/4 plans creep
zone
Relais d'alarme : .. ...................... ................ 100mA / 24V
Pouvoir tamper anti-ouverture :.................. 100 mA / 30V
Temps de maintien en alarme ................... 3 s
Température de fonctionnement : .............. -10℃ ÷ +55℃
Humidité relative admissible : .................. .. 95%
MTBF théorique : ................. ...................... 120.00 0 heures
Dimensions (h x l x p) ................................ 107x61,5x43,5 mm
Poids : ......... ...................... ...................... ... 110 g
Niveau de performances : ..... ..................... EN50131-2-4, Degré 2,
CLASSE II
ACCESSOIRES EN OPTION
• Rotules pour IR15 - DT15 - DT15AM (10 pcs.) Réf. 80SP1E00113 / Réf.
80SP1F00113
INSTRUCTIONS
• Installer l e déte cteur sur des surfaces rigides, non exposées aux
vibrations, à une hauteur comprise entre 2 et 2,2 m en fonction d es
diagrammes typiques de détection, de manière à ce que l e détecteur
détecte les dép l acements qu i croisent la zone protégée et que le module
micro-onde dé tecte les mouvem ents en approche. Eviter de placer le
détecteur à proximité de sources de chaleur o u de l’exposer à la lumière
directe du soleil.
• Eviter le réfléchissement de l' énergie électromagnétique sur de grandes
surfaces (par exemple, miroirs, parois métalliques, etc.).
• Eviter de pointer le détecteur sur des l ampes fluorescentes ou de le
placer à proximité de celles-ci.
• Eviter de créer, du fait de meubles, d’étagères , etc., des zones invisibles
à l'i ntérieur de l’espace pr otégé, qui permettraient à un intr us de se
déplacer. Eviter la présence d'animaux dans la zone protégée.
• En cas d’insta lla tions à des hauteurs supérieures à 2,1 m, il est conseillé
d'utiliser la rotule o ptionnelle, en inclinant le d étecteur de manière à
adapter au mieux les champs de couverture aux nécessités effectives.
INSTALLATION SANS ROTULE
Pour déposer le ca pot du détecteur, ôter la vis de fermeture (si présente) et
appuyer sur l’ergot de fixation. Pour enlever le circuit imprimé, él argir l ’une
des attaches E1-E2 (Fig. 2).
Attention : ne pas toucher le détecteur pyro-électrique avec l es doigts
Fond en plastique du détecteur (Fig. 2) :
F1-F4 = PRE-PERÇAGE POUR LA FIXATION ANGULAIRE
A-B = PRE-PERÇAGE POUR LA FIXATION SUR SURFACE PLANE
C-D = PRE-PERÇAGE POUR LE PASSAGE DES CABLES
Fixer le fond en plastique à la paroi à l’aide des vis et des chevilles, en
veillant à ce que leu rs têtes ne soient pas en contact avec la carte
électronique. Reposer le circuit sur le fond en plastique.
INSTALLATION AVEC ROTULE
Les m a nuels d'utilisation complets des r otules sont disponibles sur l e site
www.elkron.com.
DESCRIPTION BOITE A BORNES
I Entrée Inhibit
- + Alimentation 12V
NC TAMP Contact N.F.
NC ALL Contact N.F. du relais d'alarme
PREMIERE ALIMENTATION
Une fois alimenté, le détecteur entre dans la phase d'initialisation, au cours
de laquelle les trois LED clignotent, puis res tent allumées. Au terme de
cette phase (d’une durée d’en viron 60 secondes), l e détecteur est
opérationnel. Dans cette modalité, indépendamment de l’état du cavalier
LED OF F, le détecteur affichera les détections de la micro-onde, celles de
l’infrarouge et l ’état d’Alarme pour permettre à l ’installateur de vérifier le
fonctionnement. Cette condition perdure pendant 20 minutes.
Au bout de c délai, le détecteur affichera :
si LED O N (cavalier en place), uniquement les alarmes via l a LED
bleue ;
Si LED OFF (cavalier NON en place), uniquement d’éventu elles
mémoires.
Pour le test de portée, procéder comme suit :
MW (Micro-onde)
Régler le trimm er (portée 0,5 - 15 mt) en fonct i on de l a zone à protéger, e n
vérifiant les détections de MW à travers la LED VERTE.
Note : la portée MW doit être réglée su r la valeur minimum nécessaire ; en
effet, les micro-ondes étant en mesure de passer à travers les murs, elles
peuvent détecter des perturbations ou d es m ouvements à l’extérieur du
local à protéger.
INFRAROUGE (PIR)
Appliquer la façade en plastique et, LED éteintes, se déplacer dans la zone
concernée, en vérifiant la détection du PIR à travers la LED JAUNE.
FONCTIONS
AUTOMATIC ECO
Le détecteur est doté d’un algorithme spéci al qui minimise le s ém issions de
la Micro-onde. Sans nécessairement raccorder l’entrée Inhibit, le détecteur,
à travers le m onitorage des m ouve ments dans l’espace, détermine si
l’installation est s ous/hors tens ion. Cett e condi tion l ui permet de li miter au
maximum les émissions de Micro-onde l orsque l’installation est hor s
tension, pour ne pas irradier i nutilement l es perso nnes pré sentes dan s la
zone concernée. Cet avantage n’est pas obte nu au détriment de la
sensibilité de détection ou de l’immunité aux fausses alertes.
LED OFF - Cavalier désactivé (configuration d’usine : activé)
Il désactive les signalisations de détection , tout en maintenant habilitées
celles relatives aux mémoires.
FONCTIONS AVEC ENTREE INHIBIT
Ces fonct io ns sont activées/désact ivé es à travers l a m ise sous/hors tension
de l’installation. A ce propos, l‘on considère :
• 12V sur l’entrée INHIBIT = installation hors tension
• 0V sur l’entrée INHIBIT = installation sous tension
HABILITATION LED A DISTANCE - CONDITION RE QUISE : LED OFF
Lors de la mise ho rs t ension de l’i nstallation, le détect eur se p répare pour
le rétablissement des signalisations de d étection. Les signalisa tions seront
rétablies d ès la prem ière détection ef fectuée e t ell es demeureront act ives
pendant 30 s.
MEMOIRES
Lors de la mise hors tension de l’installation, la mémoire de la première
alarme inte rvenue ser a affichée, comme i ndiqué dans l e TAB.1
(AFFICHAGES D’ET AT MEMOIRE) . La m émoire sera réinitialisée lors de
la mise sous tension successive de l’installation.
DELAI DE MEMOIRE POUR L ’UTILISATION D’ENTREES
TEMPORISEES
Temps de sortie : les alarmes qui surviennent au cours des 30 premières
secondes après l’activation de l’installation, sont effacées.
Temps d’entrée : les alarmes qui surviennent 3 0 secondes avant la
désactivation de l’installation, sont effacées.
DECLARATION UE DE CONFORMITE SIMPLIFIEE
Le soussigné, URMET S.p.A., déclare q ue l’équipement radioélectrique du
type DÉTECTEUR À DOUBLE TECHNOLOGIE DT15 est con forme à la
directive 2 014/53/UE. Le texte co mplet de la décl aration UE de conf orm i té
est disponible à l’adresse internet suivante: www.elkron.com .
LES BONS GESTES DE MI SE AU REBUT DE CE PRODUIT (Déchets
d’équipements électriques et électroniques)
Ce sym bol e apposé sur le produit, ses a ccessoires ou sa
documentation indique que ni le produit, ni ses acce ssoires
électroniques usagés (chargeur, c asque audio, câble US B,
etc.), ne peuvent être jetés avec les autres déchets ménagers.
La mise au rebut i ncontrôlée des déchets présentant des
risques environnementaux et de santé publique, veuillez sép arer vos
produits et accessoir es usagés des autres déchets. Vous favoriserez ainsi
le recyclage de la matière qui les compose dans le cadre d’un
développement durable.
D E RUS
SVK UK
PIR+M W SPENTO ACC ESO SPENTO
PIR+M W OFF ON OFF
AFFICHAGES D’ETAT MEMOIRE
PIR+M W ETEINT ALLUME ETEINT
RIVELATORE A DOPP IA
TECNOLOGIA
DUAL TECHNO LOGY
DETECTOR
DÉTECTE UR À DOUBLE
TECHNOLOG IE
COVER