741426
5
Zoom out
Zoom in
Vorherige Seite
1/12
Nächste Seite
mode after three minutes and goes back to normal mode. In order to set the detector to constant Test mode, positioning the
DIP Switch 1 the reference to the DIP Switch position table.
SLEEP TIME
time between the detection of a movement and the next movement
<
<
N
N
O
O
T
T
E
E
>
>
In such cases it is advisable to use the Walk Test function and check the outcome on the App and portal where available
and / or on the system's local devices (eg keyboards).
Mounting and installation method
Step 1: After having performed the Walk Test to confirm that the detector is within the coverage range, select corner or surface
mounting.
Step 2: Loosen the screws and remove the cover.
Step 3: According to the user's preferences, mount the detector in the required position with or without rotating bracket.
Mounting without rotating bracket:
The rear base of the detector is provided with a hole arrangement when the plastic is thinner to allow mounting. The
two hole arrangements (A) are used to fix on a surface while the four hole arrangements (C) are used for fixing in a
corner, as shown in the following figure.
<
<
N
N
O
O
T
T
E
E
>
>
After having perforated the hole arrangements, check that the device is waterproof and restore waterproofing, if
necessary, e.g. with silicone.
1) Perforate the appropriate hole arrangements on the cover of the base. Use arrangements "A" for mounting on surface.
Use arrangements "C" for mounting in corner.
2) Using the template for the hole,make two holes in the flat surface or four holes in the corner
surface.
3) Insert the anchor bolts if the device is fixed to plaster or bricks.
4) Install the base cover in the anchor bolt with the mounting screws provided.
5) Reposition the upper cover on the base and firmly press the upper part until it clicks (as shown
on the right).
6) Tighten the locking screw.
Mounting with rotating bracket:
A rotating bracket is provided to allow a flexible mounting option. This allows a rotating bracket to be fixed to a surface/in
a corner and to an arm of the bracket to be fixed to the detector. Once installed, the detector may be separated easily
from the bracket to replace the batteries, for example, and then fixed back again with equal ease. This also makes it
possible to adjust the horizontal detector for better coverage.
1) Using the rotating shaft as template, make holes in the mounting site,
either on a surface or in a corner: 2 holes in position B for a surface, 4
holes in position D for an angle.
2) Insert the anchor bolts if the device is fixed to plaster or bricks.
3) Fasten the rotating bracket in the anchor bolts with the flat side in direction
of the wall. The arm of the bracket must face towards the person
performing the mounting operation, with the joint on top.
4) Fasten the arm of the bracket to the cover of the base of the detector with
the pointy ends facing the opposite directions with respect to the detector,
with the joint on top.
5) Arrange the detector on the hooks of the rotating bracket.
6) Adjust the detection angle arranging the arm of the bracket on one of the holes of the top of the rotating bracket then
tighten the top screw as shown.
Surface
mounting
Corner
mounting
Fastening screw
Fastening screw
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elkron EIR600 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info