8 DS80HP8A-001F
Function overview
1. Configuration dip switch
Light indication activation
The LED groups 1-2-3 blink to indicate various conditions of the system and may be programmed by means of SW2 as shown in
the Dip Switch table.
When SW2 is in the ON position, the LEDs will stay on after the siren has stopped sounding until the system is switched
off.
When SW2 is in the OFF position, the light alarm will be off if the siren stops sounding.
Alarm time
The siren alarm time is determined by Dip Switches SW3 and SW4.
When SW3 and SW4 are in the OFF position, the alarm lasts for 3 minutes (default).
When SW3 is in the OFF position and SW4 is in the ON position, the alarm lasts for 5 minutes.
When SW3 is in the ON position and SW4 is in the OFF position, the alarm lasts for 10 minutes.
When SW3 and SW4 are in the ON position, the alarm lasts for 1 second.
Exit/entrance confirmation/delay sound volume control
The volume of the siren may be programmed using Dip Switched SW5 and SW6
When SW5 is in the OFF position and SW6 is in the ON position, the siren volume is low.
When SW5 is in the ON position and SW6 is in the OFF position, the siren volume is medium.
When both SW5 and SW6 are in the ON position, the volume of the siren is high (default).
<
<
N
N
O
O
T
T
E
E
>
>
The signalling sounds and the LED cannot be deactivated by using the Dip Switches.
Chime function (not managed on MP500/xx systems)
When SW7 is moved to the ON position, the siren activates an acoustic signal whenever a Chime control is received from
the control unit.
No chime signal is generated when SW7 is moved to the OFF position (default).
2. Others
Alarm memory
In case of alarm, the siren produces a short sound when the system is deactivated to inform the user that an alarm occurred while
they were away.
Alarm time
The alarm time setting of the siren which is set by means of Dip Switches SW3&4, determines for how long the siren must sound if
no signal is received from the control unit.
Furthermore:
If the alarm time set in the control unit is higher than that set on the siren, the alarm time will be the one set on the siren. If the alarm
time set in the control unit is lower than that set on the siren, the alarm time will be the one set on the control unit.
If the system is off and a tamper alarm occurs and is enabled, the alarm time will be the one set on the siren.
Tamper
The siren is protected from attempts to open the cover and tear the siren from the surface on which it was mounted.
The tamper alarm is a sound and light alarm which lasts for the time set on the siren itself.
If the tampering condition persists, the siren will emit a series of five sound alarms whenever the system is armed or when the
tamper control is activated to indicate a fault.
The temperature function can be temporarily deactivated using the respective deactivation function. The siren will stop monitoring
tampering attempts for an hour. This function was designed mainly to allow replacing the battery or to move the siren and install it in
another position. The control unit will return the function automatically back to ON after one hour.
State indications
The siren can activate the following states when the system is turned on/off.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elkron HP600 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Elkron HP600

Elkron HP600 Kurzanleitung - Deutsch, Englisch, Französisch, Italienisch - 16 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info