6 DS80IR2E-001B
see the instruction manual of the control unit to complete the learning procedure.
Proceed with the installation after having ascertained that the detector is working in the desired position.
Mounting method
The detector was designed to be mounted on a flat surface or in a corner using the fixing screws and the anchor bolts provided.
Hole arrangements are provided on the base where the plastic is thinner and may be broken for mounting. The two hole
arrangements are used to fix on a surface, while the four hole arrangements are used for fixing in a corner, as shown in the following
figure.
Surface mounting
I. Remove the fixing screws and the cover.
II. Perforate the appropriate hole arrangements on the inner side of the
base.
III. Using the template for the holes, make the holes in the surface.
IV. Insert the anchor bolts if the device is fixed to plaster or bricks.
V. Screw the base into the anchor bolts.
VI. Screw the cover onto the base.
Corner mounting:
I. Perforate the four arrangements for corner holes.
II. Using a template for the holes, make the holes in the corner.
III. Insert the anchor bolts.
IV. Screw the base into the anchor bolt.
V. Screw the cover onto the base.
Installation
Choose the position of the detector, i.e. either in a corner or on a
surface.
After having selected the installation position, follow the procedure
described above to mount the detector.
Press the Test button to enter Test mode. Move in the protected area
and observe when the LED lights up to check that the detection
coverage is adequate.
Installation is complete when the detection coverage is appropriate.
Installation advice
The detector was designed to operate with a detection range of 12 metres when it is mounted at 2 metres from the ground.Take the
following guidelines into consideration to optimise detector use.
It is advised to install the detector in the following positions:
Mount the detector at a height of 1.9-2.0 metres to optimise performance:
Mount in a place were pets cannot access the detection area.
Mount it in a position in which an intruder would normally cross the field of vision of the detector from one side to the other.
Mount it in a corner to have the widest view possible.
Mount it where the field of vision is not obstructed, e.g. by curtains, ornaments etc.
Restrictions
Do not position the detector directly facing a door protected by the door contact because the wireless signals of the door contact
and of the detector could be transmitted in input at the same time, causing the signals to cancel each other out.
Do not install the detector fully exposed to direct sunlight.
Do not install the detector in areas in which devices which could cause sudden changes of temperature in the detection area
are present, such as air conditioning units, radiators etc.
Avoid large size obstacles in the detection area.
Do not point directly towards source of heat, such as fires or boilers, and do not install over radiators.
Avoid moving objects in the detection area, i.e. curtains, soft furnishings etc.
Technical specifications
Power supply: 1 battery CR123A 3V
Battery life: 5 years (typical value, may vary according to use)
Two-way radio frequency: 868 MHz
Infrared range: max 12 m with 110° angle
Working temperature range -10°C – +45°C
Dimensions: 53.2mm X 67mm X 89.2mm
Weight: 300g
Compliant under EN 50131 Grade 2, Class
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, URMET S.p.A. declares that the radio equipment type: INFRARED DETECTOR IR600 is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.elkron.com
ELKRON
Tel. +39 011.3986711 - Fax +39 011.3986703
www.elkron.com mail to: info@elkron.it
ELKRON
is a trademark of URMET S.p.A. Via Bologna 188/C –
10154 Torino (TO) Italy
HU
www.urmet.com
U
H
Coverage diagram
Hole arrangements for
corner fixing x 4
Hole
arrangements for
fixing on surface
x 2 (inner)
MADE IN TAIWAN
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elkron IR600 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Elkron IR600

Elkron IR600 Kurzanleitung - Deutsch, Englisch, Französisch, Italienisch - 8 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info