detected. If there should be a significant number of
errors (due to a hardware or software problem), the
device will go off-line in order to not affect other data
on the bus. The AT CS command lets you see both
the transmitter (Tx) and the receiver (Rx) error counts,
in hexadecimal. If the transmitter should be off (count
>FF), you will see ‘OFF’ rather than a specific count.
CSM0 and CSM1 [ CAN Silent Monitoring off or on ]
The ELM327 was designed to be completely silent
while monitoring a CAN bus. Because of this, it is able
to report exactly what it sees, without colouring the
information in any way. Occasionally (when bench
testing, or when connecting to a dedicated CAN port),
it may be preferred that the ELM327 does not operate
silently (ie generates ACK bits, etc.), and this is what
the CSM command is for. CSM1 turns it on, CSM0
turns it off, and the default value is determined by
PP 21. Be careful when experimenting with this. If you
should choose the wrong baud rate then monitor the
CAN bus with the silent monitoring off, you will disturb
the flow of data. Always keep the silent monitoring on
until you are certain that you have chosen the correct
baud rate.
CTM1 [ set the Timer Multiplier to 1 ]
This command causes all timeouts set by AT ST
to be multiplied by a factor of 1. Note that this currently
only affects the CAN protocols (6 to C). CTM1 is the
default setting.
CTM5 [ set the Timer Multiplier to 5 ]
This command causes all timeouts set by AT ST
to be multiplied by a factor of 5. Note that this currently
only affects the CAN protocols (6 to C).
This command was originally added (as JTM5) to
assist with the retrieving of some J1939 messages.
We have since had several requests to allow it to
affect all CAN modes, and so have modified the JTM5
code and added the new CTM1/CTM5 commands. If
using CTM5, we caution that the Adaptive Timing code
does not monitor changes in the setting, so we advise
turning it off (with AT AT0).
By default, this multiplier is off.
CV dddd [ Calibrate the Voltage to dd.dd volts ]
The voltage reading that the ELM327 shows for an
AT RV request can be calibrated with this command.
The argument (‘dddd’) must always be provided as 4
digits, with no decimal point (it assumes that the
decimal place is between the second and the third
digits).
To use this feature, simply use an accurate meter
to read the actual input voltage, then use the CV
command to change the internal calibration (scaling)
factor. For example, if the ELM327 shows the voltage
as 12.2V while you measure 11.99 volts, then send
AT CV 1199 and the ELM327 will recalibrate itself for
that voltage (it will actually read 12.0V due to digit
roundoff). See page 29 for some more information on
how to read voltages and perform the calibration.
CV 0000 [ restore the factory Calibration Value ]
If you are experimenting with the CV dddd
command but do not have an accurate voltmeter as a
reference, you may soon get into trouble. If this
happens, you can always send AT CV 0000 to restore
the ELM327 to the original calibration value.
D [ set all to Defaults ]
This command is used to set the options to their
default (or factory) settings, as when power is first
applied. The last stored protocol will be retrieved from
memory, and will become the current setting (possibly
closing other protocols that are active). Any settings
that the user had made for custom headers, filters, or
masks will be restored to their default values, and all
timer settings will also be restored to their defaults.
D0 and D1 [ display of DLC off or on ]
Standard CAN (ISO 15765-4) OBD requires that
all messages have 8 data bytes, so displaying the
number of data bytes (the DLC) is not normally very
useful. When experimenting with other protocols,
however, it may be useful to be able to see what the
data lengths are. The D0 and D1 commands control
the display of the DLC digit (the headers must also be
on in order to see this digit). When displayed, the
single DLC digit will appear between the ID (header)
bytes and the data bytes. The default setting is
determined by PP 29.
DM1 [ monitor for DM1s ]
The SAE J1939 Protocol broadcasts trouble codes
periodically, by way of Diagnostic Mode 1 (DM1)
messages. This command sets the ELM327 to
AT Command Descriptions (continued)
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elm 327 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info