ELM327
55 of 94ELM327DSJ Elm Electronics – Circuits for the Hobbyist
www.elmelectronics.com
Using J1939
This section provides a few examples which show
how to monitor an SAE J1939 data bus, and how to
make requests of devices that are connected to it.
To begin, you will need to configure the ELM327
for J1939 operation, at the correct baud rate. Protocol
A is predefined for J1939 at 250 kbps, which is what
most applications require. To use protocol A, send:
>AT SP A
Protocols B and C may also be used with J1939,
if you wish to experiment with other baud rates. To use
them for J1939, the option value (in PP 2C or 2E) must
be set to 42, and the baud rate divisor (in PP 2D or 2F)
must be set to the appropriate value. Perhaps the
simplest way to provide an alternate rate is to use the
AT PB command, that allows you to set both the
options byte (which is always 42), and the baud rate
divisor (which is 500k ÷ the desired baud rate) at the
same time. For example, to set protocol B for J1939
operation at 500 kbps, simply send:
>AT PB 42 01
then send:
>AT SP B
to begin. Note that this setting will not be maintained if
the IC is reset, so if you want a more permanent
setting, you should store the values in PP 2C and 2D.
J1939 often provides slowly broadcast information,
and for this reason, the ELM327 automatically sets a
response timeout (AT ST time) as required by the
message (typically 1.25 seconds, but it varies). If this
is too long for you, or if you are using an older version
of our product (ie. v1.3a or older), then you might want
to set this time manually (we recommend starting with
AT ST FF for the older ICs). You will not do any harm
if you set the timeout with a newer chip, but the timing
will not be optimal as you will stop the ELM327 from
varying the setting based on the type of message
being received.
The ELM327 also offers one other variation on the
timer setting - the ability to extend the AT ST time by
switching a x5 timer multiplier on (see the JTM5
command description). This may be useful or even
necessary when requesting data that will have a
multiline response, if similar data is already flowing. In
these circumstances, there can only be one message
like this at a time on the bus, so the response to your
request might have to wait while an initial response
completes (and this could take more than the normal
ST time, since broadcast responses must be spaced
at least 50 msec apart). If you know that a reply should
be coming, and you are seeing ‘NO DATA’ responses,
then send AT JTM5 and try it again, as that may be
the problem. Restore the timer multiplier to normal with
AT JTM1.
Once the J1939 protocol is selected, and the
timeout value has been adjusted, the ELM327 is ready
for a command. The first one that we will send is called
a DM1 or ‘diagnostic message 1’, which provides the
currently active diagnostic trouble codes. DM1 is one
of more than 50 predefined diagnostic messages, and
is special in that it is the only one that is broadcast
continually over the bus at regular intervals. The
ELM327 has an AT command that is used to obtain
the DM1 trouble codes:
>AT DM1
If you are connected to a vehicle, you should now
see messages printed at one second intervals. If you
are only connected to a single device (for example,
with a simulator on the bench, or to a device with a
single CAN data port), you may see data with
<RX ERROR printed beside it. This is because the
receipt of the data is not being acknowledged by any
device on the bus (certainly not the ELM327, as it is by
default a completely silent monitor). See our ‘AN05 -
Bench Testing OBD Interfaces' application note for
more information on this, and some advice on what to
do. If you have a v1.4b or newer chip, you do not have
to take special measures, however. Simply turn off the
silent monitoring with:
>AT CSM 0
and there should be no more RX ERRORs. Once you
have this sorted out, repeat the request. If all goes
well, you should see several replies, similar to this:
00 FF 00 00 00 00 FF FF
00 FF 00 00 00 00 FF FF
You will likely need to stop the flow of data by
pressing any key on the keyboard. This is because the
DM1 command is actually a special form of a
monitoring command, and all monitoring needs to be
stopped by the user. The response means that there
are currently no active trouble codes, by the way.
55

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Elm 327 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info