7 | ENGLISH
Q: How do I include or exclude the sensor into a different Z-wave controller
A: Inclusion:
Have your Z-wave Controller entered inclusion mode, press the On/off button of
the sensor three times.
A: Exclusion:
Have your Z-wave Controller entered inclusion mode, press the On/off button of
the mini switch three times. Once the node has been included, the LED will go
into an interval of two seconds on and two seconds off.
A: Reset:
Press the On/Off button three times to enter inclusion mode. Within one second,
press On/Off button again until LED is off. The home ID and node ID will be
cleared and reset to factory default.
A: Association:
Have a Z-wave remote module entered in association mode first. Press link
button three times within 1.5 seconds to enter association mode. The LED will
blink for 0.5 sec. and then go off.
A: Configuration Basic Set Level:
The Basic Set Command is sent with value to have the receiving device
recognize the value for controlled level, for example, if the Basic Set Command
sent to dimmer with value, the dimmer would activate the luminance according to
the value, for example:
0 : Off
1 – 99 : On (Binary Switch Device)
Dim Level (Multilevel Switch Device)
Configuration command:
Function: Basic Set Level
Parameter number: 1
Size: 1
Range: 0 ~ 99
Default: 99
A: Configuration Amount of Delay (seconds):
This is applied to determine the delay time setting to send the Basic Set Off
command when the manual switch input at NO (open).
Example:
0: immediately Off
1 – 127: delay 1 ~ 127 second to Off
Configuration command:
Function: Amount of delay
Parameter number: 2
Size: 1
Range: 0 ~127
Default: 1