GENERAL
Carefully read the following important information regard-
ing installation safety and maintenance. Keep this infor-
mation booklet accessible for further consultations.
The appliance has been designed for use in the ducting
version (air exhaust to the outside – Fig.1B), filtering
version (air circulation on the inside – Fig.1A) or with
external motor (Fig.1C).
SAFETY PRECAUTION
1. Take care when the cooker hood is operating simulta-
neously with an open fireplace or burner that depend on
the air in the environment and are supplied by other than
electrical energy, as the cooker hood removes the air
from the environment which a burner or fireplace need for
combustion. The negative pressure in the environment
must not exceed 4Pa (4x10-5 bar). Provide adequate
ventilation in the environment for a safe operation of the
cooker hood.
Follow the local laws applicable for external air evacua-
tion.
Before connecting the model to the electricity net-
work:
- control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to
the network and the socket is suitable. If in doubt ask a
qualified electrician.
2. WARNING !
In certain circumstances electrical appliances may be
a danger hazard.
A) Do not check the status of the filters while the
cooker hood is operating
B) Do not touch bulbs or adjacent areas, during or
straight after prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker
hood
D) Avoid free flame, as it is damaging for the filters
and a fire hazard
E) Constantly check food frying to avoid that the over-
heated oil may become a fire hazard
F) Disconnect the electrical plug prior to any mainte-
nance.
G) This appliance is not intended for use by young
children or infirm persons without supervision
H) Young children should be supervised to ensure they
do not play with the appliance
I) There shall be adequate ventilation of the room
when the rangehood is used at the same time as appli-
ances burning gas or other fuels
L) There is a risk of fire if cleaning is not carried out
in accordance with the instructions
This appliance conforms to the European Directive EC/
2002/96, Waste Electrical and Electronic Equipment
(WEEE). By making sure that this appliance is disposed
of in a suitable manner, the user is helping to prevent
potential damage to the environment or to public health.
he
symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to a
suitable electric and electronic appliance recycling
collection point.
Follow local guidelines when disposing of waste.
For more information on the treatment, re-use and
recycling of this product, please contact your local
authority, domestic waste collection service or the shop
where the appliance was purchased.
INSTALLATION INSTRUCTIONS
Assembly and electrical connections must be carried
out by specialised personnel.
• Electric Connection
The appliance has been manufactured as a class II,
therefore no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load
indicated on the description label. Where a plug is pro-
vided, the cooker hood must be installed in order that the
plug is easily accessible.
An omnipolar switch with a minimum opening of 3mm
between contacts, in line with the electrical load and
local standards, must be placed between the appliance
and the network in the case of direct connection to the
electrical network.
The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm.
If a connection tube composed of two parts is used, the
upper part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same
conductor used to circulate hot air or for evacuating
fumes from other appliances generated by other than an
electrical source.
Before proceeding with the assembly operations, remove
the anti-grease filter(s) (Fig.7) so that the unit is easier
to handle.
In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
• FIXING TO THE WALL
Drill the holes A respecting the distances indicated (Fig.2).
Fix the appliance to the wall and align it in horizontal
position to the wall units. When the appliance has been
adjusted, definitely fix the hood using the screws A (Fig.5).
For the various installations use screws and screw an-
chors suited to the type of wall (e.g. reinforced concrete,
plasterboard, etc.). If the screws and screw anchors are
provided with the product, check that they are suitable for
the type of wall on which the hood is to be fixed.
• FIXING THE DECORATIVE TELESCOPIC FLUE
Arrange the electrical power supply within the dimensions
of the decorative flue. If your appliance is to be installed in
the ducting version or in the version with external motor,
prepare the air exhaust opening. Adjust the width of the
support bracket of the upper flue (Fig.3). Then fix it to the
ceiling using the screws A (Fig.3) in such a way that it is in
line with your hood and respecting the distance from the
ceiling indicated in Fig.2. Connect the flange C to the air
exhaust hole using a connection pipe (Fig.5).
Insert the upper flue into the lower flue. Fix the lower flue
to the hood using the screws B provided (Fig.5), extract
the upper flue up to the bracket and fix it with the screws
B (Fig.3).
If your appliance has the lower connections indicated as in
Fig. 4 A, the fixing to be carried out is that shown in Fig. 6
A
To transform the hood from a ducting version into a filtering
version, ask your dealer for the charcoal filters and follow
the installation instructions.
• FILTERING VERSION
Install the hood and the two flues as described in the
ENGLISH
GB
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Etna A 4485 T wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info