105 INSTALLATION
Above a 60 cm oven of the Etna brand
Recess height minimum 600 mm. Ventilation is
via plinth and rear of oven.
Where there is a oven, a gap of at least 560 x
6 mm should be made at the front. Cut out
ventilation openings "A" + "B" (100 cm
2
). Make
an opening in the side wall "C" of the kitchen
cupboard for leading the connection cable
through.
The hob may only be combined with Etna
ovens, not with combi-microwave ovens.
Ensure that the connection cables hang
freely. If there is a drawer underneath the
hob, make sure that the contents do not
project above the edge of the drawer and
interfere with the ventilation.
Installation of the induction hob above a
combimicrowave oven, a 90 cm Etna oven or
an oven of a different brand
Saw out the ventilation opening(s), making
sure that the total surface of the holes is a
minimum of 100 cm
2
. See the drawing, for
example, showing 2 holes.
Fit a protective plate between the oven and
the hob. The plate should be at least 10 mm
thick and heat-resistant (85 °C). The space
between the underside of the hob and the
protective plate must be at least 50 mm.
To protect the air flow, fit a protective panel -
of the same material as the protective plate -
between the protective plate and the hob.
Ventilation is via the adjoining cupboards.
Install the appliance in such a way
that the power plug remais
accessible always.
min.
104
INSTALLATION
Ventilation
The electronics in the appliance require
cooling. The ventilation openings are located
on the underside of the appliance. It must be
possible for cool air to be drawn in through
these openings. The appliance is fitted with
outlet openings at the front and bottom. The
kitchen unit will require a few modifications to
allow optimum cooling of the hob.
Above drawer or fixed panel
Saw out the ventilation openings
(min. 100 cm
2
).
Ventilation is via plinth and rear of cupboard.
Do not allow the ventilation openings
on the underside of the appliance to be
blocked by a drawer.
Where there is a drawer, a gap of at least
560 x 6 mm should be made at the front.
The distance between drawer A and the hob
should be a minimum of 10 mm.
No extra modifications for ventilation need be
made where there is a fixed panel.
Ventilationprotection
The electronics in the appliance require
cooling. The cool air is sucked from behind
the cupboard and blown out at the front and at
the bottom in the front of the appliance. The
hob can only operate if there is sufficient
circulation of fresh air.
The appliance will switch off after a
short time if there is not enough
circulation.
See to it that the traverse lath does not hinder
the airflow. Plane or saw the lath oblique if
necessary.
min.
min.