MINI THERMOMETER ETH 5000
OPERA TING INS TRUC TIONS
Item no . 39 32 48 / V ersion 02/13
INTENDED USE
The thermometer displa ys the temper ature at the mounting loc ation.
The pow er is to be supplied by a bat tery only (type , see “T echnic al Data”). Do not use an y other
power supply .
Any use other than that de scribed above is not permitt ed and can damage the product . In addition,
it can lead t o dangers such as short-circuit , fi re, etc .
Alwa ys observe the saf ety instructions and all other in formation included in these oper ating
instructions.
This product c omplies with the applicable national and Eur opean regulations. All names o f compa-
nies and product s are the trademark s of the respectiv e owners. All right s reserved.
P A CKA GE CONTENT S
Thermometer
Operating Instructions
SAFETY INS TRUC TIONS
ƽ
Please read all o f the operating instructions bef ore using the product for the fi rst
time; they cont ain important information about the corr ect operation. The w arranty
will be void in the ev ent of damage caused by f ailure to observ e these safet y inst-
ructions! W e do not assume any liability f or any resulting damage!
W e shall not accept liability f or damage to property or pers onal injury caused by
incorrect handling or non-complianc e with the safety ins tructions! In such cases,
the warr anty will be null and void.
The “Hand” symbol indicat es special tips and operating in formation.
F or safe ty reasons , any unauthorised con version and/ or modifi cation of the pr oduct is not
permitted. Ne ver dismantle the product.
The product is int ended exclusiv ely for use in dry interior s; it must not get damp or wet .
The manuf acturer does not acc ept any liability f or incorrect or inac curate r eadings or any
consequenc es resulting fr om such readings.
This product is not a t oy and does not belong in the hands of childr en. Only use the product
out of the re ach of children; the pr oduct contains a batt ery and small parts that could be sw al-
lowed.
Condensation may f orm when the product is brought fr om a cold room int o a warm one .
Theref ore, w ait until it has reached r oom temper ature bef ore using it.
Do not leave p ackaging material lying ar ound careles sly . It may become a danger ous plaything
for childr en.
Handle the product with c are. It c an be damaged by impact, blow s, or by being dr opped, even
from a lo w height.
INSTR UCTIONS F OR BA TTERIES AND RE CHARGEABLE
BA TTERIES
Batt eries/ rechar geable batt eries do not belong in the hands of children.
Do not leave b atteries lying ar ound in the open. There is a danger that childr en or pets may
sw allow them. If they ar e sw allowed, consult a doct or immediately .
Leaking or damaged batt eries/ r echargeable bat teries in cont act with the skin can cause acid
burns; theref ore, use suit able safety glo ves.
Batt eries/ rechar geable batt eries must not be short-circuit ed, opened or thrown int o fi re.
There is a risk o f explosion!
Do not rechar ge normal, non-recharge able batteries; risk o f explosion! Only char ge recharge-
able batt eries that are intended f or this purpose; use a suitable bat tery charger .
Make sur e that the polarity is corr ect when inserting the battery / r echargeable bat tery (pay
attention t o plus/+ and minus/-).
SET -UP
Place the devic e on a stable, le vel and robus t surface .
Prot ect valuable furniture surf aces b y using a suitable underlay; otherwise , it may cause
scr atch marks.
Don‘t place the thermometer in the dir ect vicinity of an y heat source; otherwis e the measured
value might be wr ong. F or this reas on, direct solar r adiation should also be avoided.
INSERTING /REPLA CING THE BA TTER Y /RE CHARGEABLE
BA TTER Y
Open the batt ery compartment on the rear of the housing and ins ert one battery of t ype AAA/
Micro with the c orrect polarity . T he correct polarit y is indicated in the batt ery compartment.
After ins erting the battery , the de vice operat es again.
Close the bat tery compartment again.
The batt ery must be replaced, if the c ontrast on the displa y fades or the displa y does no longer
functions.
Rechar geable batterie s can be used. Howe ver , the lower oper ating voltage (r echargeable
batt ery = 1.2 V , batt ery 1.5 V) and lower cap acity will reduc e the operating time.
When the batt ery is replaced, the sav ed maximum and minimum values o f the thermo-
meter will be delet ed.
OPERA TION
The sensor f or the thermometer is inside the casing and thus als o shows the temper a-
ture in the inner c asing. Therefor e, t o obtain more accur ate measur ed values, do not hold
the device in y our hand or place it near a heat sour ce.
The measur ement display needs about 15 to 30 minut es to stabilis e and to display an
accur ate value .
In normal mode the display indicat es the temper ature‘s curr ent value , the minimum value and
the maximum value simult aneously .
T o dele te the data memory and to s tart the recor ding of maximum and minimum value again,
pres s the RESET button.
Pres s the °C/°F button t o toggle the display unit of the t emperatur e value.
MAINTENANCE AND CLEANING
The product doe s not require an y maintenance and should ne ver be disassembled for an y reason.
Please use a clean, s oft, and dry cloth for cleaning.
Do not use any chemic al cleaning agents, as they c an discolour the plastic casing.
DISPOS AL
a) Product
Electronic de vices are r ecyclable w aste materials and mus t not be disposed of in the
household w aste!
Dispose of an uns erviceable product in ac cordanc e with the relev ant statutory r egu-
lations.
Remov e the battery if ther e is one inserted and dispose o f it separat ely from the
product.
b ) Batteries and R echargeable Batt eries
As end user , you are r equired by law (B attery Regulation ) to r eturn used batt eries and rechar ge-
able batt eries. Do not dispose of us ed batteries in the household w aste!
Batt eries/ rechar geable batt eries contain harmful mat erials and are labelled with the
symbol sho wn to indicate that dispo sal in the household wast e is forbidden. The s ym-
bols of the rele vant hea vy metals are: Cd=C admium, Hg=Mercury , Pb=Lead ( marked
on batt eries/ rechar geable batt eries, e. g. under the rubbish bin symbol shown to the
left).
Y ou c an return y our used batterie s/ rechar geable batt eries free of char ge at the of-
fi cial collection points of your c ommunity , in our stor es, or at place s where batt eries
or rechar geable batterie s are sold!
Y ou ther eby fulfi l y our st atutory obligations and contribute t o the protection o f the environment .
TE CHNICAL D A T A
Operating v oltage: 1.5 V /DC (Batt ery type AAA/Micro )
Service lif e: appro x. 2 years
Measuring r ange: -10 t o +50 °C
Resolution: 0 . 1 °C
Accur acy: +/-1 °C (0 t o 40 °C)
+/- 2 °C (other r anges )
Dimensions: 56 x 55 x 21 mm
These oper ating instructions are a public ation by Conr ad Electronic SE, Klaus-C onrad-S tr . 1,
D-92 2 40 Hirschau ( www .c onrad.c om). All rights including tr anslation reserv ed. Reproduction b y
any method, e .g. photocop y , microfi lming, or the c apture in electronic dat a proces sing syst ems
requir e the prior written appr oval b y the editor . Reprinting, also in part, is prohibit ed. These ope-
rating ins tructions repres ent the technical st atus at the time of printing. Changes in technology
and equipment res erved.
© Cop yright 2013 by Conr ad Electronic SE.