If the Cool Perfect is not in use or you are cleaning or carrying out maintenance on it, turn it
off and remove the plug from the socket. Always turn off first and then remove the plug!
When you switch off the Cool Perfect, wait at least 3.5 minutes before reusing to avoid
damaging the compressor.
Avoid the use of extension cables if you can. If this is unavoidable, use a cable with diameter
of at least 1.5 mm² and do not let it cross any walking routes!
This unit needs max. 7 Amp power. So never connect any other equipment that requires a
high current to the same group. Otherwise, you may cause a power outage.
Do not move the Cool Perfect by tugging on the electric cable and never remove the plug
from the socket by pulling the cable.
Do not use the unit if the electrical cable, plug or device is damaged or broken. The device,
plug and/or cable must be repaired/replaced by an electrician or another suitably qualified
person. Repairs by unqualified persons will result in the guarantee becoming null and void
and could lead to dangerous situations!
Safety in relation to coolant R290:
Read these warning carefully.
This device contains the coolant R290. R290 is a coolant that complies with the relevant
European Directives. Never perforate the coolant circuit. R290 is flammable (GWP 3)!
Never use substances other than those recommended by the manufacturer for the defrosting
process.
This device must be used and stored in a room that does not contain sources of ignition, such
as open flames or gas and electrical devices in operation.
Do not perforate any of the components of the cooling circuit and do not set light to the
device.
If the device is installed, working or stored in an un-ventilated you must take measures to
prevent fire or explosions caused by leaked coolant. Ensure that there are absolutely no
sources of ignition (such as fire, heaters, sparking electrical equipment, lit cigarettes, etc.) in
the same room!
The device must be stored in such a way that mechanical defects are prevented.
Do not install, operate or store the device in a room smaller than 12m² (CP90) / 15 m² (CP120
& 150).
R290 is odourless, which means that you cannot smell leaks!
Persons working on the cooling circuit must be in possession of the correct qualifications that
state the person in question is competent to use coolant in accordance with a special
evaluation that is recognised by the sector association.
The repairs must be executed on the grounds of the recommendations of the manufacturer of
the device. Maintenance and repairs that require the assistance of other qualified persons
must be executed under supervision of someone who is specialised in the use of flammable
coolant.
For maximum effect:
Use a unit that is suitable for the area to be heated/cooled.
Do not place the Cool Perfect in the vicinity of a heat source or in direct sunlight.
Close windows and doors.
Keep curtains or hatches closed during the sunniest hours in the day
Keep filters clean
Modify temperature and ventilation settings once the area has reached the required condition.