22
Note: Switch the pump on ONLY if the drainage hose is installed. If the pump is switched on
without a drainage hose installed, the water from the water outlet will flow out onto the floor and
could cause damage.
When you remove the hose that you installed, you must replace the short, pre-shaped hose
(which is supplied attached to the rear of the device) and lead this through the channel opening
in the water tank. NB: this is important otherwise water damage may occur!
Tapping options
At the back of the device, at the bottom, there is a tap. This
tapping point can be used to remove residual water from the
device before moving or storing it. Remove the plug at the
back of the device. Don't forget to push the plug back into
the hole securely afterwards. Otherwise, there may be a
leak when you use the device again.
Displays
Both displays (top and front) show the air humidity in the room.
If you enter the desired air humidity, this setting will be shown for a few seconds.
If you set an ON/OFF time using the timer, the display will show the set number of hours for a
few seconds.
If the air humidity is lower than 35%, the display will show ‘LO’ (low)
If the air humidity is higher than 95%, the display will show ‘HI’ (high)
Operation panel
1. [ Swing ] button
This button can be used to tilt the air outlet up and down for better air circulation in the room.
2. [ Pump ] button (See installation)
With this button, a pump can be switched on to pump the water away. The water is not
captured in the water tank but can be drained to a drainage point so that the water tank doesn't
have to be emptied. The maximum pumping height is 3 metres.
Note: If you use continuous drainage, always check to ensure there are no leaks in the hose