16. Do not damage the electric cable and replace it never yourself. Do not place heavy
objects on the cable and don’t lead it around sharp corners. Keep it away from heat
sources. Don’t use a damaged electrical cable any more!
17. When the device is used continuously, arrange a suitable drain. Do not use the device
at temperatures around or below freezing point.
18. Make sure that the machine is always in a stable and perfectly horizontal position.
Otherwise, water may enter into the device and get through to essential elements,
with fire, shock, etc. to possible result.
19. Do not use the device near water or in spaces such as bathrooms and laundry rooms.
If the device is too damp, fire or electric shock may occur.
20. When you don’t use the device for an extended period of time, disconnect the plug
from the socket.
21. Repairs to the appliance, cord and plug must only be carried out by qualified
technicians.
Safety in relation to coolant R290
1. This device contains the coolant R290. R290 is a coolant that complies with the
relevant European Directives. Never perforate the coolant circuit. R290 is flammable
(GWP 3)!
2. This device must be used and stored in a room that does not contain sources of
ignition, such as open flames or gas and electrical devices in operation.
3. Do not perforate any of the components of the cooling circuit and do not set light to
the device
4. If the device is installed, working or stored in an un-ventilated you must take
measures to prevent fire or explosions caused by leaked coolant. Ensure that there
are absolutely no sources of ignition (such as fire, heaters, sparking electrical
equipment, lit cigarettes, etc.) in the same room!
5. The device must be stored in such a way that mechanical defects are prevented.
6. Do not install, operate or store the device in a room smaller than 14m².
7. R290 is odourless, which means that you cannot smell leaks!
8. Persons working on the cooling circuit must be in possession of the correct
qualifications that state the person in question is competent to use coolant in
accordance with a special evaluation that is recognised by the sector association.
9. The repairs must be executed on the grounds of the recommendations of the
manufacturer of the device. Maintenance and repairs that require the assistance of
other qualified persons must be executed under supervision of someone who is
specialised in the use of flammable coolant.
10. Disassembly and recycling of the device must be performed by a certified technician.
Eurom dehumidifier
The Eurom dehumidifiers are designed to reduce the air humidity in a room and, as a
result, raise levels of comfort and improve the conditions for the storage of goods.
The dehumidifier combines a practical design with top quality and simple controls. This
makes it ideal for use in industrial, scientific and medical environments such as