Switch the device on using the Power button.
1. Cooling function
Press on Mode until the Cool light shows on the display.
The display shows 25°C.
Set the desired temperature using the Temp+(Up)/Temp-(Down) button. The
display shows the set temperature. The temperature can be set to between 16
and 31°C.
Maintain an interval of at least 3 minutes between each on and off.
2. Dehumidifying function
Press on Mode until the Dry light shows on the display.
Check that the water outlet is correctly connected (see page 35).
The display automatically shows 2°C under room temperature.
The temperature cannot be changed.
The fan speed is set to low automatically.
Maintain an interval of at least 3 minutes between each on and off.
3. Ventilation function
Press on Mode until the Fan light shows on the display.
The display shows 25°C.
Use the Speed button to set the output to Low or High.
The temperature cannot be changed.
4. Timer function
Automatic start: the air conditioning unit is off. Press on Timer and select the
desired temperature using Temp+(Up)/Temp-(Down). If the display shows 4,
for example, the air conditioning unit will start in 4 hours.
Automatic stop: the air conditioning unit is on. Press on Timer and select the
desired temperature using Temp+(Up)/Temp-(Down). If the display shows 8,
for example, the air conditioning unit will switch off in 8 hours.
The timer can be set to between 1 to 24 hours.
5. Night function
Press on Mode until the Cool light shows on the display.
Set the desired temperature.
Press the ‘Sleep’ button; after 1 hour, the temperature will increase by 1°C and
after 2 hours, by 2°C.
The unit will continue to work on this setting.
Water outlet
During the cooling process, the device removes water from the air. This largely
evaporates but any excess water is collected in the water reservoir. If the water
reservoir in the device is full, the compressor and the motor will stop automatically
and the ‘water tank full’ light (W.F.) will come on. In
this event, switch the air conditioning unit off and
remove the plug from the socket. Empty the water
tank by removing the cap from the water drainage
point (see picture) and draining the tank into a drain
or receptacle. Do not forget to replace the cap again
afterwards! You can then switch the air conditioning
unit back on.
When dehumidifying, more water is removed from
the air. This is why you must connect a hose to the
water drainage hose (see site 35) during dehumidifying and run this to a drain (at a
lower point).