- SPV550 semi PI SPV750i SPV900i SPV1100i: Your pump is fitted with automatic
aeration, allowing air to escape when it is submerged in water. The air bubbles that appear
are not a sign of a defect but are perfectly normal.
OPERATION
Before use, check that the values of the socket to which you wish to connect the pump
correspond to those on the type plate on the pump itself (230V-50Hz) and that the socket is
earthed (max. 30mAmp). Make sure that no people present in the space to be pumped out
(cellar/boat/pond etc).
Automated function
Once you have plugged the device into the socket, the pump will switch on automatically when
the water exceeds the set minimum level and switch off when the set minimum level has been
obtained.
This means that the pump can be left on at all times and will keep the water in a cellar or boat,
for example, at the required level. Bear in mind that this pump is not designed to be used
continuously; it must be switched off at regular intervals.
Despite the fact that the pump works automatically, regular supervision is required in order to
ascertain that it has not encountered any functional problems and that it has not been damaged
(see also: overheating safeguard).
During automatic operation, the pump will turn itself off when there is still some water in your
cellar/boat/pond because the automatic float switch needs space in which to switch. If you wish
to pump out the remaining water, we advise you to use the pump manually in order to do so.
Placing the pump at the lowest point (or in a hollow) will allow you to remove almost all of the
remaining water. Make sure it does not dry out!
Manual function
If used manually, your pump will start to work when you insert the plug into the socket and you
ensure that the float switch is set to ‘on’. You do this by holding the float switch upright (float
cable underneath). The pump will continue to work if you hold the float in this way (or fix it like
this). Stop the pump from functioning as soon as liquid is no longer being pumped; the pumped
liquid also cools the motor and without this cooling effect it may overheat and break down!
Always supervise a pump that is working manually; drying out will lead to increased wear and
tear!
If your pump has run dry it will not automatically aerate itself. Switch it off (remove the plug from
the socket) and move the pump from side to side so that air can escape. Thereafter, you may
use the pump as usual. You are advised to use the pump manually for short periods only. You
should keep your eye on the pump at all times during manual functioning.
OVERHEATING SAFEGUARD
Your submersible pump is equipped with an overheating safeguard. This switches the pump off
automatically if the motor gets too hot. Once it has cooled down sufficiently, the pump will
automatically switch on again.
There is always a cause for overheating: the fan may have become jammed, a bearing may be
worn etc. etc. and if the cause is not removed, the device will overheat once again. If this
process is repeated too often it may cause serious damage to your pump. Try to establish what
is wrong and resolve the problem. If the pump needs to be opened up you must take it to your
supplier or an accredited professional.
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eurom SPV750I wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info