Menu 02 – SET CHRONO
Sub-menu M2 – 1 ENABLE CHRONO
Allows all chrono-thermostat functions to be enabled or disabled.
Sub-menu M2 – 2 PROGRAM DAY
The daily programmable chrono-thermostat functions can be enabled, disabled and set.
Two on/off times can be set defined by the times set according to the table below, where the OFF setting tells the clock to ignore the command:
Sub-menu M2 – 3 PROGRAM WEEK
The weekly programmable chrono-thermostat functions can be enabled, disabled and set.
The weekly programmer has 4 independent programs whose final effect involves the combination of the 4 individual programs. The programmer can be
enabled or disabled. Moreover, if the time is set to OFF, the time clock ignores the corresponding control.
In each program you will find: Switch-on time, Switch-off time, Set stove heat output, Room temperature, Days of the week for which the programme is
to be active. Monday is 1 and Sunday is 7.
Caution: set carefully to prevent overlapping of different activation times of different programmes on the same day.
Sub-menu M2 – 4 PROGRAM WEEK-END
The programmable chrono-thermostat functions can be enabled, disabled and set for the week-end (days 5 and 6, or Saturday and Sunday).
SUGGESTION: if you still do not know exactly the result you want to obtain, enable only one programme at a time to avoid confusion and unwanted
stove switching on and off.
Disable the daily programme if you want to use the weekly programme. If you use the weekly programme for 1, 2, 3 and 4 programmes, never enable
the week-end programme.
Always disable the weekly programme before enabling the week-end programme.
Menu 03 – SELECT LANGUAGE
Use this command to select one of the languages available.
Menu 04 – MODE STAND-BY
Activates the "STAND-BY" mode that switches the appliance off after the room temperature has been higher than SET after the time defined by a pre-set parameter,
or when the external thermostat is satisfied.
After switching off after this condition, restarting will only be possible when the following condition is verified: the actual room temperature is lower than the set one,
after which the appliance will switch on automatically once the pre-set time has elapsed.
Menu 05 – MODE BUZZER
Set it to “OFF” to disable the buzzer.
Menu 06 – LOAD INITIAL
This function is important if the product is new, or if it is switched off due to insufficient pellets in the hopper.
INITIAL IGNITION MUST BE PERFORMED BY AUTHORISED PERSONNEL ONLY, NOT BY THE PURCHASER.
CONTACT THE SUPPORT CENTRE TO SEND A SPECIALIST TECHNICIAN.
It allows a pellet preload to be carried out for a predefined time when the product is switched off and cold. Start with button P1 and stop with button P4. The initial
load is only enabled if the appliance is in the Off state.
Menu 07 – STATE STOVE
It displays the instant status of the appliance reporting the status of the various devices connected to it. A few examples are included in the following pages. The
following will be displayed: status times (including on, off, working, etc.), pellet load and heat output, fume temperature and fume motor speed.
Menu 08 – SETTINGS TECHNIC
Menu only for technicians and installers.
11. USER FUNCTIONS
Standard operation of a control board properly installed in a stove is described below with reference to the functions available to users. The indications listed below
refer to a control board fitted with programmable chrono-thermostat.
Stove ignition
Ensure that there are pellets in the hopper, that the burn pot is correctly positioned and free from any combustion residues and then close the door. To turn the unit
on, press button P4 for a few seconds. The display shows that the stove is on.
Start-up phase
The appliance performs the start-up phases in sequence according to the methods defined by the parameters that manage levels and times. The display will show
the wording START, as there is no pellet loading but the exhaust blower is in operation. LOAD PELLET state will occur where the pellets are being loaded into the
burn pot. Once the pellets have started to burn and the fume temperature increases, the display will show the wording FLAME LIGHT, a transition phase between
ignition and operating heat output.
Ignition fault
If the fume temperature has not reached the minimum permitted value after a predefined time, at a rate of 2°C/min, the appliance goes into alarm status.
If there are unburnt pellets inside the burn pot, it is necessary to empty the burn pot before switching the stove on again. Pellet waste and potential bursting inside
the combustion chamber will thus be avoided.
If the pellets have begun to burn but the alarm state persists, wait until all the pellets are burning and then switch on again.
Check that there are pellets inside the hopper.
Stove operational
At the end of the start-up phase, if no problems occurred, the stove enters its normal working mode.
When the fume temperature is the same as that set by the parameters, the fan is switched on.
Once the set temperature has been reached, the appliance will go into MODUL- and automatically work at minimum power.
Selection Meaning Available values
START 1 switching-on time time - OFF
STOP 1 switching-off time time - OFF
START 2 switching-on time time - OFF
STOP 2 switching-off time time - OFF
20
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eva Calor ARIA 50 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Eva Calor ARIA 50

Eva Calor ARIA 50 Bedienungsanleitung - Deutsch - 31 seiten

Eva Calor ARIA 50 Bedienungsanleitung - Französisch - 31 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info