The thermostat switches off the Auger tube, being connected in series to its power supply, the control board reports the alarm status (alarm LED on) by showing
the message “AL7 SAFETY THERMAL” on the display and the stove switches off.
AL8 FAILURE DEPRESS - No negative pressure alarm
The alarm is triggered whenever the external pressure switch detects a pressure higher value below the trigger threshold. The pressure switch switches off the
Auger tube, being connected in series to each other, and the control board reports the alarm status (alarm LED on) by showing the message “AL8 FAILURE
DEPRESS” on the display. The stove switches off.
05.5 ELECTRONICS WITH REMOTE CONTROL p. 4 F-5
(Pellet stoves)
PROPER FUNCTIONING AND CONTROL ADJUSTMENT DEVICES
Control panel
The control panel shows the information concerning the stove status. Several types of data can be displayed and the settings available according to the access level
can be modified by entering the menu.
Depending on the selected mode and on their position on the display, the data visualized may acquire different meanings.
PANEL DESCRIPTION
DISPLAY (P0)
BUTTON (P1) - Decrease:
When in programming mode, use this button to modify/decrease the selected menu value. When in WORK/OFF, use instead this button to decrease the room
thermostat temperature value or stove heat output.
BUTTON (P2) - Increase:
When in programming mode, use this button to modify/increase the selected menu value. When in WORK/OFF, use instead this button to increase the room
thermostat temperature value or the stove heat output.
BUTTON (P3) - ON/OFF Unlocking:
Hold this button down for two seconds to manually switch the stove on or off respectively depending on its initial status OFF or START.
Press it once to go back to the previous menu and up to the initial screen.
Should have any alarm blocked the stove, press this button to unlock the stove and subsequently switch it OFF.
BUTTON (P4) – Set Room Temperature value:
When in WORK mode, use this button to access the set room temperature value. In menu mode, use this button to go back to the previous menu item or, in
programming mode, to go back to the previous sub-menu item. Any change is automatically saved.
BUTTON (P5) – Set Heat Output value:
When in WORK mode, use this button to access the heat output value. In menu mode, use this button to move to the next menu item, while, in programming
mode, to move to the subsequent sub-menu item. Any change is automatically saved.
BUTTON (P6) – Return:
Serves to return to the previous menu.
BUTTON (P7) - Set/menu:
Use this button to access user and technician parameter menu. After entering the menu, use this button to access the next sub-menu level or set the value and
move to the next menu item when in programming mode.
BUTTON (T1) ON/OFF button: to manually switch the stove on or off
BUTTON (T2) + button: heat output increase
BUTTON (T3) - button: heat output decrease
LED (L1) Signal LED: it confirms that signal has been received
LED (L2) Alarm LED: it indicates the stove alarm status. Clear using on/off button
MENU
Press P7 (MENU) button to access the menu.
It includes several items and levels to access settings and control board programming. The menu items providing access to the technical setting are protected
by access code.
Menu M2 – SET CLOCK
Use this function to set current time and date. The control board is equipped with a lithium battery guaranteeing the internal time clock a 3/5 year-long life.
Menu M3 – SET CHRONO
Submenu M3 -1 ENABLE CHRONO
The programmable thermostat functions can be disabled and enabled.
Submenu M3 - 2 PROGRAM DAY
The daily programmable thermostat functions can be enabled, disabled and set
It is possible to set two on/off times defined by the times set according to the table below. If the value is set to OFF, the time clock ignores the control:
settingmeaningavailable values
START 1 switchin on time time - OFF
STOP 1 switching off time time - OFF
START 2 switchin on time time - OFF
STOP 2 switching off time time - OFF
Submenu M3 - 3 PROGRAM WEEK
The weekly programmable thermostat functions can be enabled, disabled and set.
The weekly programmer consists of 4 independent programmes which can be combined together in different ways.
The weekly programmer can be enabled or disabled.
Moreover, if the time is set to OFF, the time clock ingnores the corresponding control.
N.B.: set the programming carefully in order to avoid overlapping of switching on and/or off times of different programmes on the same day.
Submenu M3 - 4 PROGRAM WEEK-END
The programmable thermostat functions can be enabled, disabled and set for the week-end (days 6 and 7, or Saturday and Sunday).
TIP: if you still do not know exactly the result you want to obtain, enable only one programme at a time to avoid confusion and unwanted stove switching on and off.
Disable the daily programme if you want to use the weekly programme. If you use the weekly programme for 1, 2, 3 and 4 programmes, never enable the week-end
programme.
Always disable the weekly programme before enabling the week-end programme.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Eva Calor Duna wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.