Approaching the water set, the stove goes into modulation and when the set is passed, the stove goes into modulation and then stand-by.
Below water set the stove comes on again and resumes operation.
The stove in no way considers the temperature measured by the ambient sensor of the same stove.
Water takes priority.
Mode 3
WITH RESPECT TO THE THERMOSTAT AND TO THE TEMPERATURE OF THE WATER.
Having set the water temperature, commence operation of the stove.
1- With the thermostat open the stove goes into modulation and then stand-by.
2- With the thermostat closed the stove is working.
Nearing Set Water, the stove goes into modulation and remains in modulation. It only goes into stand by mode when the thermostat opens the contact. It turns
on when the thermostat closes the contact.
The stove in no way considers the temperature measured by the ambient sensor of the same stove.
The thermostat takes priority.
Menu 05 – BUZZER MODE:
Set it to “OFF” to disable the buzzer.
Menu 06 – ENABLE FAN:
The heating stoves with built-in room fan have this menu. With this menu it is possible to enable or disable the room fan. The fan power is pre-set according to the
operating power of the stove.
Menu 07 – INITIAL LOAD
This function is important if the stove is new or if the stove is off due to the absence of pellets in the hopper.
INITIAL IGNITION MUST BE PERFORMED BY AUTHORISED PERSONNEL ONLY, NOT BY THE PURCHASER.
CONTACT THE SERVICE CENTRE THAT WILL SEND OUT A SPECIALIST TECHNICIAN.
Use this function to load pellets for a period of 90 seconds when the stove is switched off and cold. Start with button P1 and stop with button P4.
Menu 08 – STOVE STATUS:
This function displays the current status of all the devices connected to the stove. A few examples are included in the following pages.
08.3 USER FUNCTIONS
Standard functioning of a control board properly installed on a forced air pellet stove is described below with reference to the functions available to users. The
indications listed below refer to a control board fitted with programmable chrono-thermostat.
Stove ignition
Ensure that there are pellets in the hopper, that the burn pot is correctly positioned and free from any combustion residues and then close the door.
To turn on the stove, press button P4 for a few seconds. The display shows that the stove is on.
Start-up phase
The stove performs all the steps of the start-up phase according to the parameters concerning its levels and times. The display will show the wording ON, as there
is no pellet loading but the exhaust blower is in operation. PELLET LOADING state will occur where the pellets are being loaded into the burn pot. Once the pellets
have started to burn and the fume temperature is increased, the display will show FIRE ON, a transition phase between ignition and operating power.
Ignition fault
After the Pr01 time has elapsed, if the flue gas temperature has not reached the minimum permitted value, parameter Pr13, reached with the power of 2°C/min,
the stove goes into alarm status.
If there are unburned pellets inside the burn pot, it is necessary to empty the burn put before switching on the stove. Pellet waste and potential bursting inside the
combustion chamber will thus be avoided.
If the pellets have started to burn but the FAILED IGNITION alarm status persists, it is necessary to wait for all the pellets to burn and then to re-ignite.
Check that there are pellets inside the hopper.
Stove operational
Once the start-up phase is completed, the stove switches to work mode which represents the normal operating mode.
If the stove temperature is the same as the set power, the pump starts.
Changing set room temperature
To change the room temperature, simply press the P2 button. The display shows the current SET temperature value.
Changing the temperature setting of the heating stove
To change the room temperature, simply press the P1 button. The display shows the current SET temperature value.
External thermostat/chrono-thermostat use
If you want to use an external programmable thermostat, connect it to the TERM clamps (connector CN7 pin 7-8).
External thermostat
External chrono-thermostat
The stove external thermostat is enabled when the contact is closed with stove on.
Room temperature reaches the set value (SET temperature)
When the set room temperature value is reached or the fume temperature has reached the Pr13 value, the stove heat output is set automatically to the minimum
value, MODULATION mode.
If the stove is in the STAND-BY mode, it switches off after the period of time set by Pr44 and after reaching the SET temperature.
Restart occurs after the following condition has occurred: Tambient > (TSET + Pr43)
The same situation is obtained when the heating stove temperature reaches the same level as that set. The modulation status is evident and, if enabled, STANDBY
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Eva Calor EV 24 wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.