11.3.8 Timer ON 2 switching on 2 hours minutes
Press button 2and then button 8repeatedly to select UT08.
Press then statuses 1and 2
to set timer hours and minutes. Upon finishing, press button 8repeatedly to exit the technical menu or wait
20 seconds.
11.3.9 Timer OFF 2 switching off 2 hours minutes
Press button 2and then button 8repeatedly to select UT09. Press then statuses 1and 2
to set timer hours and minutes. Upon finishing, press button 8repeatedly to exit the technical menu or wait
20 seconds.
11.3.10 Enabling Timer 2
Press button 2and then button 8repeatedly to select UT10. Press then statuses 1and 2
to enable (On) or disable (Off) the timer. LED 3switches on upon completing timer enabling.
Upon finishing, press button 8repeatedly to exit the technical menu or wait 20 seconds.
11.3.11 Parameter percentage adjustment
The pellet load and fume exhaustion percentages can be modified using parameter Cpel and Casp respectively:
•CASP is the fume exhaustion percentage variation.
•CPEL is the pellet load percentage variation. Modify the parameters as follows:
•Enter the UT04 technical menu.
•Press buttons 1 and 2 repeatedly until the display shows “c9”. Hold the buttons down to move more
rapidly.
•Press button 8 to confirm.
•Press button 8 to select Cpel or Casp.
•Press buttons 1 and 2 to modify the value.
•Cpel and Casp values range from -5 to +5. Each step corresponds to a variation equal to ± 5 %.
with respect to the basic value. (PR06 ÷ PR10 for pellet loading and PR18 ÷ PR22 for fume exhaust blower).
•The default values are:
Cpel = 0 Casp = 0
11.4.Alarms
11.4.1 “NO ACC” alarm.
The alarm is triggered when the fume temperature does not increase by a gradient equal to 3
°
C/min
during the LOAD
WOOD or FIRE ON phases and does not reach the temperature set by PR13 within the time set by PR01:
•The switching-on phase is interrupted and the stove switches off.
•The display shows the message “ALAR/ No/
A
cc
”.
•Use the control panel or remote control to clear the alarm (hold on/off button down for at least 2 seconds).
11.4.2 “NO FIRE” alarm.
If the stove switches off during the working mode (the fume temperature reaches a value below the PR13 parameter), the
stove enters the switching-off phase.
•The display shows the message “ALAR/No/Fire”.
•Use the control panel or remote control to clear the alarm (hold on/off button down for at least 2 seconds).