off. If the power outage takes place when the stove is in ECO STOP mode, the stove will return to this mode regardless of how long the outage period is. In all
other cases, the stove switches off after the power supply is restored. The stove can also enter a safety alarm condition. In this case you need to reset the safety
thermostat placed on the back of the stove.
Insufficient pellet level
The stove is equipped with a sensor that controls the level of pellet. The stove does not start if the pellet level is too low. During the work phase the stove will
operate at minimum heat output.
ALARMS
To each event corresponds an alarm that is activated after the delay time indicated when the event occurs.
If the cause of the alarm is not removed within this period of time, the stove enters the alarm condition, shuts down immediately and enables the fume fan and the
exchanger fan at maximum speed. The devices are then switched off once the fume temperature reaches the lowes set value. Each alarm condition, except for
"no fire" is recorded in the alarm history.
ALARM DESCRIPTION
No fire
the fume temperature does not meet the necessary conditions for ignition
FAIL
the fume temperature does not meet the necessary conditions for stabilisation
Al. SmokeT
the fume temperature reached and exceeded the maximum set threshold
No fire
the fume temperature dropped below the minimum set threshold
Al. Vacuos / Al depr.
the vacuum switch signalled an anomalous pressure/vacuum
Al. Safety
the thermostat detected an excessive temperature (exceeding the relevant threshold)
Al. roomP.
the room sensor is connected, not working properly (short circuit or stopped)
Al. smokeP
the fume thermocouple i connected, not working properly (short circuit or stopped)
Al. blower
the fume fan is blocked or rotates at a speed lower than 300 rpm.
Al. flux
the value detected by the flow sensor indicates a malfunction. The flow control is enabled but the flow rate cannot be adjusted automatically.
T. elect (°C)
the temperature inside the stove and therefore of the electronic board exceeded the maximum threshold of 70° c.
Reset
Press the P2 (ON/OFF) key to silence the alarm, then hold the P2 (ON/OFF) button to switch off the stove.
If the stove does not switch off, contact technical assistance. Avoid disconnecting the stove from the mains if the flame did not disappear completely.
05.8 IR REMOTE CONTROL (optional)
(Pellets stoves - Pellet stove with oven – Pellet kitchen – Pellet kitchen with oven – Pellet inserts)
IR Remote control
The stove control panel is set up to receive certain functions via remote control.
•Ignition/shutoff function: pressing the 1 and 6 buttons at the same time turns the stove on or off.
•Power regulation: during normal operation, pressing the 5 and 6 buttons, labelled with the flame, lets you set one of
the stove power levels.
•Temperature regulation: during normal operation, pressing the 2 button and then the 1 and 2 buttons, labelled with the
thermometer, lets you set the temperature.
06. CLEANING AND MAINTENANCE
INTRODUCTION
The stove requires a simple yet constant cleaning to guarantee top efficiency and proper functioning.
Constant maintenance by a qualified technician is recommended.
The stove should be cleaned before the cold season because it can sometimes get clogged during the summer (by nests for example) preventing exhaust fumes
to flow regularly.
At the beginning of the season and in case of wind, a build-up of residue in the pipe may lead to fires. Should this happen, find below a few pieces of advice to
follow:
•Block air supply to the pipe immediately;
•Throw sand or kitchen salt, and not water, to extinguish fire and coals;
•Keep objects and furniture away from the burning pipe.
ALSO TO PREVENT THIS TYPE OF FAULT YEARLY CLEANING OF THE VENT PIPE IS ESSENTIAL, REMOVING DEPOSITS OR ANY POCKETS OR
OBSTRUCTIONS.
ATTENTION:
•USE A DRY CLOTH TO CLEAN THE STOVE EXTERNALLY
•THE AUGER TUBE MUST BE COMPLETELY EMPTIED FROM PELLETS WHEN USING THE STOVE FOR THE LAST TIME AT THE END OF THE
SEASON. THE AUGER TUBE MUST REMAIN EMPTY TO PREVENT IT FROM BECOMING CLOGGED BY SAWDUST RESIDUES THAT HAVE
SOLIDIFIED DUE TO MOISTURE.
DAILY CLEANING
Any cleaning operation must be performed when the stove is completely cold:
•Empty the ash drawer: vacuum it out or dispose of the ashes in a waste bin.
•Vacuum the combustion chamber: check that there are no embers that may still be lit. In this case your ash vacuum cleaner will
catch fire.
•Remove the ash inside firebox and on door.
•Wipe the glass with a damp cloth or a damp ball of newspaper dipped into the ash. If the operation is performed with the stove hot
there is a risk of the glass exploding.
ONLY FOR PELLET KITCHEN
It is also possible to raise the plate (or glass) and aspirate the fume circulator.
When the fume circulator is clean ensure the plate is well positioned.
ATTENTION: USE A DRY CLOTH TO CLEAN THE STOVE EXTERNALLY DO NOT USE ABRASIVE MATERIALS OR PRODUCTS THAT MAY CORRODE
OR LIGHTEN THE SURFACES.
MANUFACTUTER LIABILITY
The manufacturer shall not be held liable against any direct and/or indirect, criminal and/or third party liability arising from:
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Eva Calor Futura 19.5 kW wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.