ALARM ACTIVE NO LIGHTIN- - Stove switching-off during working mode alarm
The alarm is triggered when, during normal working mode, the flame goes out and the fume temperature falls below the minimum threshold set by Pr13 parameter.
If the pressure switch (meter pressure) detects a value below the trigger threshold, it immediately switches off the Auger tube (to which it is connected in series)
while the control board acquires this change in status through the AL2 clamp in CN4. The message “FAILURE DEPRESS” appears on the display and the stove is
immediately switched off.
ALARM ACTIVE SAFETY THERMAL - General thermostat alarm
If the general safety thermostat detects a value exceeding the trigger threshold, it immediately switches off the Auger tube (to which it is
connected in series), while the control board acquires this change in status through the AL1 clamp in CN4. The message “SAFETY
THERMAL” appears on the display and the stove is immediately switched off. Unscrew the black cap on the back of the stove and press the
button to reset the contact.
ALARM ACTIVE FAN FAILURE - Damaged exhaust blower alarm
Whenever the exhaust blower stops working properly, the stove switches off immediately and the message FAN FAILUREappears on the display.
The stove
switching off phase starts immediately.
CERCA CAMPO
This message appears when the remote control cannot connect to the emergency panel. Make sure that board is powered or that the emergency panel (receiver)
is connected properly.
Transmission Unit Setup:
The stove must be connected to the main power supply. Press simultaneously the keys (P1) and (P2) for about 3-4 seconds until SCEGLI UNITAʼ appears and
then select with the keys (P1) and (P2 ) the transmission unit (1-2-3 ...). The remote controls are supplied with transmission units set to 0 (default unit). Hold down
the ON / OFF button (P3) for about 3 seconds to store. The remote control is ready for normal operation.
These operations must be carried out within 30 seconds of the stove feeding.
05.6 ELECTRONICS WITH REMOTE CONTROL LCD pag. 4 F-6
(Air-tight stoves)
PROPER FUNCTIONING AND CONTROL ADJUSTMENT DEVICES
The remote control system replaces the classic display of the traditional pellet stoves. It comes with charger, rechargeable batteries, support and plugs with screws
for wall mounting. It can also work with alkaline batteries.
Installing the remote control system on the stove:
•cut off the power supply to the stove.
•enable the power supply and press any free key on the handheld remote control (that is not associated with another stove within the operating field of the
remote control) after the “beep”.
Stand-by and recharge:
The remote control goes automatically into stand-by if not used for more than 30. " Press any key or simply move the remote control to wake up from stand-by.
The handheld remote control has a battery life of about 3 days. After this period, it no longer responds and it is therefore necessary to recharge it using the battery
charger supplied with the product; we recommend that you charge it for at least 60 minutes (the time necessary for reaching the minimum battery level that will
allow the device to work properly). We generally recommend that you place it in the appropriate support when not using it. The functions assigned to the remote
control will not be lost; not even if completely discharged.
In case of damage of the remote control you can operate the stove using the special emergency switch placed on the back of the stove.
Emergency switch:
In case the remote control does not work, you can turn on and off the stove with the button positioned on the rear of the stove near the power cord. (See image
on p. 15 EMERGENCY SWITCH)
PANEL DESCRIPTION
Button (P1) Programmable thermostat access key.
Button (P2) On/off key.
Button (P3) Hold the P3 key to view useful information.
Button (P4) Press the P4 key until the ROOM TEMPERATURE menu
appears on the display and then change the value using the P5 and P6
keys.
Button (P5) Up key. You can also use it to scroll through the menus.
Button (P6) Down key. You can also use it to scroll through the menus.
QUICK MENU
The P4 key (SET/MENU) allows you to open the menu functions. Press it for several times to browse through the pages below:
Maximum heat output setting (MAXIMUM POWER): Use the P5 and P6 keys to increase and respectively decrease the maximum heat output SET. Press P4 again
to go to the next page.
ECO STOP: Use the P5 and P6 keys to switch between ON and OFF. The next P4 pressure moves to the next page. Enables or disables the ECO STOP mode.
Room temperature setting (ROOM TEMPERATURE): Use the P5 and P6 keys to increase and respectively decrease room 1 SET temperature. Press P4 again
to return to home page.
User menu
Open the main page and then hold the P4 key:
•EXIT: returns to main page.
•PRE LOADING: opens the pre-load function.
•SYSTEM STATUS: displays the page that contains information on the current status of the system.
•PELLET SET: allows the user to adapt the functionality of the system to the quality of the pellets used.
•GENERAL SETTINGS: open the "general settings" submenu.
Display (D1) current day and date.
Display (D2) current hour and minute.
Display (D3) room temperature.
Display (D4) stove status (OFF).
Display (D5) operating mode (NORMAL or PROGRAM).
Display (D6) the letter (A) next to it indicates if the room temperature is lower
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Eva Calor Giotto wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.