6.2 First ignition
Before igniting the stove, you MUST have a qualified technician perform "FIRST START-UP" and
calibration. For this purpose, we advise you to contact personnel part of our network of authorised
service centres. The company assumes no responsibility for malfunctions due to improper
installation, failure to install, incorrect first ignition, or improper use.
Make sure that electrical and plumbing connections have been performed properly. Also check
that the hydraulic system (on heating stoves and boilers) has a sufficient expansion tank for
maximum safety. Please note that expansion is calculated considering 6% of the whole volume
contained in the system. Any damage to the system or to equipment will not be considered under
warranty. The presence of the tank fitted on the unit does not guarantee adequate protection
against sustained thermal expansion of the system water.
Fill up the system through a refill valve (to be provided externally to the stove). During recovery,
it is advisable not to exceed a maximum pressure of 1 bar. Pressure can be read directly on the
pressure gauge (item 7 par. 5.5).
The water loading phase should be simultaneous to air exhaust.
Before lighting the stove, also check that the brazier is pushed back towards the rear wall
of the combustion chamber.
The first few times you light the stove, it may give off odours due to the evaporation of paint or
grease. Simply ventilate the room to make the odour go away, avoiding prolonged exposure as
vapours can be harmful to people or animals. Do not allow children to stay in the room during this
first phase.
When the tank is loaded for the first time, the feed screw must fill up for a given period. During this
time, pellets will not be distributed within the combustion chamber. To overcome this difficulty, use
the command "initial load" in menu 7 of the control panel (see further details to follow).
6.3 Ignition and normal operation
Before igniting the stove:
- Check that the furnace door is locked.
- Make sure that the pellet tank is full or contains such enough so that the stove will function for
the desired amount of time.
- Make sure that the brazier is clean, free of ashes, combustion residue or unburned pellets (if
necessary, remove the brazier and thoroughly clean it, then replace it with care in its
housing). In the event or start-up with the programmable thermostat, make sure that the
brazier is in the indicated conditions after last use.
When the stove is connected to the electrical system but not in work mode, the display will show
the message "OFF".
6.3.1 Stove start-up
To start up the stove, hold and press the start button (4) for 2 seconds
If you start the stove during the final cleaning phase, the display may show the message "WAIT
COOLING." In this case, wait for a minute before retrying ignition.
First phase. Preparation
The message "START" will appear on the display. In this phase, which lasts for about one minute,
the pellet glow plug activates and combustion chamber forced ventilation starts along with
activation of the fume extraction fan.
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eva Calor Giove wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Eva Calor Giove

Eva Calor Giove Bedienungsanleitung - Deutsch - 38 seiten

Eva Calor Giove Bedienungsanleitung - Holländisch - 90 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info