03 PRODUCT INSTALLATION
12
03.1 INTRODUCTION
INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED. INSTEAD THE FUME OUTLET MUST BE ROOF-TYPE AS
PROVIDED FOR BY NATIONAL REGULATIONS.
Eva Stampaggi S.r.l. declines any liability for any damage to persons or property arising from the failure to comply with the
points mentioned above and from non-compliant product installation.
Install the stove according to the regulations in force in the country of use.
For example, in Italy this refers to UNI 10683: 2012, which dictates 4 points
1. preliminary activities - for which the retailer/installer is responsible and liable for at the time of the inspection before definitive
installation The preliminary activities include:
installation site suitability verification;
fume evacuation system suitability verification;
external air inlet suitability verification;
At this stage it is necessary to check that the product can be safely operated and that it satisfies the relevant technical characteristics.
The safety conditions must be ascertained by means of a prior inspection.
Stoves and fireplaces are heating systems and must be installed safely and comply with the manufacturer's instructions!
2. Installation - responsibility of the installer. At this phase the aspects of installation of the product and of the fume evacuation
system are taken into account and the following issues are addressed:
safety distance from combustible materials;
chimney flue construction, smoke ducts, intubated systems and chimney cowls.
3. issuing of additional documents - responsibility of the installer.
Issuing of the technical documentation must include:
manual of use and maintenance of the appliance and of the components of the system (e.g smoke ducts, chimney flue,
etc.);
Photocopy or photograph of the chimney flue plate;
system manual: (if applicable);
Declaration of Conformity in relation to Ministerial Decree 37/08.
4. control and maintenance - responsibility of the maintenance technician who must oversee protection and maintenance of the
product during its operation over time. The operator in charge of control and maintenance of the systems for winter and summer
climate control performs these activities to a professional standard in accordance with the regulations in force. The operator, at the
end of these operations, must draw up and sign a technical inspection report in accordance with the models provided by the
provisions of this decree and the implementing rules, in relation to the type and capacity of the system, to be issued to the person
who signs a copy thereby confirming receipt and reading thereof."
03.2 VENT PIPE
STOVE CHARACTERISTICS FOR SIZING OF THE VENT PIPE
The curved front hydro 20 kW and the hydro straight front 20 kW stoves have the following characteristics:
Chimney flue draught: 12 Pa
Fume temperature: 154°C
Mass flow of fumes: 10.8 g/s
The curved front hydro 24 kW and the hydro straight front 24 kW stoves have the following characteristics:
Chimney flue draught: 13 Pa
Fume temperature: 179 °C
Mass flow of fumes: 14.3 g/s
The kantina hydro 20 kW stoves have the following characteristics:
Chimney flue draught: 13 Pa
Fume temperature: 145 °C
Mass flow of fumes: 10.9 g/s
The kantina hydro 24 kW stoves have the following characteristics:
Chimney flue draught: 13 Pa
Fume temperature: 164°C
Mass flow of fumes: 13.2 g/s
13

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eva Calor Hydro 20 kW wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Eva Calor Hydro 20 kW

Eva Calor Hydro 20 kW Bedienungsanleitung - Deutsch - 38 seiten

Eva Calor Hydro 20 kW Bedienungsanleitung - Holländisch - 90 seiten

Eva Calor Hydro 20 kW Bedienungsanleitung - Französisch - 43 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info