03. INSTALLING THE PRODUCT
23
INSTALLATION
In compliance with the current regulations for installation, the pellet thermo-stove should be installed in a ventilated place with air
that is sufficient to ensure correct combustion and therefore good operation. The room must have a volumetry of no less than 20 m3
and to ensure good combustion (40 m3/h of air), there must be a combustion air intake" that must reach a wall that connects to the
outside or to adjacent rooms provided they are fitted with external air supply vents (Ø80mm) and are not used as bedrooms or
bathrooms or, whenever a fire hazard exists, as storage rooms, garages, combustible material warehouses, etc. These air vents must
be placed in such a way that they cannot be clogged either from the outside or inside and must be protected using a grille, a metal
mesh or other suitable means provided they do not reduce the minimum section.
When it is operational, the thermo-stove can cause a negative pressure in the room where it is installed. Therefore there should not
be in the same room other naked flame devices, with the exception only of type c stoves (watertight) unless they are fitted with their
own air flow.
They must not be positioned close to curtains, armchairs, furniture or to other flammable materials.
They must not be installed in explosive or potentially explosive environments which may become explosive due to the presence of
machinery, materials or dust that can cause greenhouse gas emissions or which can easily ignite with sparks. Before attempting to
install the pellet thermo-stove, bear in mind that all fixtures or any beams made of combustible material must be placed at a safe
distance and outside the radiation area of the stove itself. Also consider that in order not to compromise the correct operation of
the appliance, it is essential to create air circulation inside its casing. This helps prevent overheating and can be achieved by respecting
the minimum distances and by creating a number of ventilation holes.
Internally, the thermo-stove is equipped with all the components for safety: automatic ventilating valve, 3-bar safety valve, expansion
tank and stove safety thermostat. Remember to discharge the hydraulic system before switching on the appliance.
The use of hosing is recommended that connects the appliance to the hydraulic system as, in the case of ordinary or extraordinary
maintenance, this makes it easy to move. It is also recommended to install a dirt separator as the electronic pump could capture the
dirt of the system and become jammed.
ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance.
Extra attention we need to do when the stove are an integration to the plant and all the machines have to work like the program.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230 V while the frequency is 50 Hz.
The electrical system where it is connected must be fitted with a conductor as required by the Regulations 73/23 EEC and 93/98 EEC.
EXTERNAL THERMOSTAT
In these thermo-stoves it is possible to install an external thermostat. This operation may only be performed by authorised personnel.
Use a 2-pole cable with everyday double insulation. In the event that the thermostat is closed, the stove functions at the power set.
If the thermostat opened, the stove would work in MODULATE mode until the thermostat closes.
First connect the stove plug to the mains and load the pellet hopper.
Be careful not to empty the entire bag at once. Perform this operation slowly.
24

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eva Calor Hydro Kantina New 20 kW wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Eva Calor Hydro Kantina New 20 kW

Eva Calor Hydro Kantina New 20 kW Bedienungsanleitung - Deutsch - 47 seiten

Eva Calor Hydro Kantina New 20 kW Bedienungsanleitung - Holländisch - 43 seiten

Eva Calor Hydro Kantina New 20 kW Bedienungsanleitung - Französisch - 43 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info