814234
9
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
The calorific value depends therefore, on the density of the wood (that varies based on its type) and on its moisture content. The heat output of the stoves is directly
affected by this factors. Depending on its moisture content, it can be indicated in:
% of humidity
Calorific heat output kcal/kg
15%
3490
20%
3250
25%
3010
30%
2780
35%
2450
40%
2300
On average, a well seasoned wood has a calorific value of 3200 kcal/kg.
06. INSTALLATION WARNINGS
06.1 HERMETIC STOVE
The hermetic wood stove body is available for outputs 8 and 12.5 kW. If properly connected by means of a suction tube, these stoves draw the combustion air and
the air necessary for glass cleaning directly from outside and not from the room where they are installed, preserving the oxygen in the room. Using coaxial tubes,
the air will be pre-warmed contributing to improved combustion and lower emissions into the atmosphere. Ideal for passive houses, they offer best comfort at the
lowest cost.
Before installation, the following indications must be respected:
Select the position where the stove is to be installed and:
Choose whether the appliance will have a rear or upper flue gas outlet.
Provide the connection to the flue pipe for the expulsion of the fumes.
Provide the external air intake (combustion air) and check for its presence: it must be drawn from a free space (not spaces where extractor fans exist or
without ventilation) or from outside.
Place the stove on the floor in a position that is advantageous for connection with the flue pipe and near the "combustion air" intake
The appliance must be installed on a floor with an adequate loading-bearing capacity. Should the existing floor not comply with the requirement above, proper
measurements must be taken (for instance, the installation of a load distribution plate).
All the structures which could catch fire if exposed to excessive heat must be protected. Flooring made from wood or inflammable materials must be protected
using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
The appliance installation must ensure easy access for cleaning of the stove, exhaust pipes and flue pipe.
This appliance is not suitable to be installed on a shared flue pipe.
During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake must be positioned at the same height of the
pipe located on the stove back. When it is operational, the stove can cause a negative pressure in the room where it is installed. Therefore there should not
be other naked flame devices in the same room.
The combustion air intake (Ø 80mm) must be connected directly to the outside or to adjacent rooms provided
they are fitted with external air supply vents (Ø 80mm) and are not used as bedrooms or bathrooms or, whenever
a fire hazard exists, as storage rooms, garages, combustible material warehouses, etc. The air vents must be
placed in such a way that they cannot be clogged either from the outside or inside and must be protected using
a grille, a metal mesh or other suitable means provided they do not reduce the minimum section. For the
connection to the external intake, it is necessary to break the pre-cuts in the lower part of the stove back and to
connect the pipes with a dedicated seal to the appropriate intake.
If the stove is to be installed in rooms where it is surrounded by combustible materials (e.g. furniture, wood
cladding, etc.), the following minimum clearances must be complied with: "SEE STOVE DATA PLATE”
The 8.5 kW stove does not have a connection to the combustion air intake.
It is however advisable, in addition to respecting the minimum distances, to install heat-resistant flame-retardant
insulating panels (rock wool, aerated concrete, etc.)
The following is recommend:
Promasil 1000
Classification temperature: 1000°C
Density: 245 kg/m³
Shrinkage at reference temperature, 12 h: 1.3/1000°C %
Cold crushing strength: 1.4 MPa
Bending strength: 0.5 MPa
Reversible thermal expansion: 5.4x10-6 m/mK
Specific heat capacity: 1.03 kJ/kg K
Thermal conductivity λ:
200°C 0.07 W/mK
400°C 0.10 W/mK
600°C 0.14 W/mK
800°C 0.17 W/mK
Thickness: 40 mm
07. INSTALLATION
Unpack the stove: be careful not to damage the product at the time of unpacking.
Check the stove's legs and adjust them so that the stove is stable.
Place the stove so that the door and any window openings are not against the walls.
After connecting the stove to the combustion air inlet join the coupling device to the flue pipe.
ATTENTION: the 8 kW and 12.5 kW stoves must be installed with a minimum of 1 meter of Ø 150 pipe, certified according to the
EN1856-2 standard.
The exhaust fume pipes must be suitable for wood-burning stoves and must therefore be made from coated steel or stainless steel,
with a diameter of 150 mm and fitted with adequate seals.
The 8.5 kW stove has a fume outlet diameter of 120 mm. Follow the same directions listed above.
9
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Eva Calor Marica wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Eva Calor Marica

Eva Calor Marica Bedienungsanleitung - Deutsch - 16 seiten

Eva Calor Marica Bedienungsanleitung - Französisch - 16 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info