11.4.3 “COOL FIRE” alarm.
It is triggered only in case of power outage. When power resumes, the stove enters a switching off phase.
•The display shows the message “CooL Fire”.
•Upon completing the switching-off cycle, the stove automatically resumes operation.
11.4.4 “FAN FAIL” alarm.
The alarm is triggered when the exhaust blower revolutions are not detected. The stove enters the switching-off phase.
•The display shows the message “Alar /Fan/Fail”.
•Use the control panel or remote control to clear the alarm (hold on/off button down for at least 2 seconds).
11.4.5 “SIC DEP FAIL” alarm.
The alarm is triggered when the pressure switch or the safety thermostat are activated:
•The stove enters the switching-off phase.
•The display shows the message “Alar /Dep/ Sic /FAiL”
•ALF and ALC LEDs flash
•Use the control panel or remote control to clear the alarm (hold on/off button down for at least 2 seconds).
11.5.Alarm log
The system alarm log registers the last 5 alarms triggered and it is accessible by entering the “E9” code in the UT04
menu. Enter the password “99” in the UT04 menu to clear the alarms.
11.5.1 Alarm visualisation.
•Enter the UT04 technical menu.
•Press buttons 1 and 2 repeatedly until message “E9” appears on the display. Hold the buttons down to
move more rapidly.
• Press button 8 to confirm.
•The display shows the error number and the type of alarm alternatively. Press button 8 again to move to the other
alarms.
11.5.2 Clearing Alarms.
• Enter the UT04 technical menu.
• Press buttons 1 and 2 repeatedly until the display shows “99”. Hold the buttons down to move more
rapidly.
•
Press button 8 to confirm and clear the log.