In compliance with the current installation regulations, the pellet heating stove should be installed in a ventilated place with air that is sufficient to ensure correct
combustion and therefore good operation. The room must have a volume no less than 20 m3 . In order to ensure good combustion (40m3/h of air) there must be a
"combustion air intake" that reaches an external wall or a wall of an adjacent room with an external air intake (Ø 80mm minimum diameter). The adjacent room
must not be a bedroom or bathroom, or contain any fire risks, such as storerooms, garages, combustible materials stores, etc. These air intakes must be made in
such a way as to avoid being blocked internally or externally, and should be covered with a grille, metal net or suitable protection, as long as the minimum diameter
is not reduced.
When it is operational, the pellet heating stove can cause a negative pressure in the room where it is installed. Therefore there should not be in the same room
other naked flame devices, with the exception only of type c stoves (watertight) unless they are fitted with their own air flow.
They must not be positioned close to curtains, armchairs, furniture or to other flammable materials.
They must not be installed in explosive or potentially explosive environments which may become explosive due to the presence of machinery, materials or dust
that can cause greenhouse gas emissions or which can easily ignite with sparks. Before installing the pellet heating stove, it must be remembered that all finishes
or any beams made of combustible material must be positioned at a suitable distance and outside the irradiation area of the stove itself; furthermore, it must be
borne in mind that in order not to compromise the correct operation of the appliances, air must be allowed to circulate inside its housing to prevent overheating,
this is possible by respecting the minimum distances and making ventilation holes.
The use of hosing is recommended that connects the appliance to the hydraulic system as, in the case of ordinary or extraordinary maintenance, this makes it easy
to move. It is also recommended to install a dirt separator as the electronic pump could capture the dirt of the system and become jammed.
07.1 ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance. Particular attention must be paid when
the stove is an integration to the system and all the equipment must operate as planned.
Avoid installations with electric cables that run close to fume pipes or hot components that are suitably insulated.
The voltage is 230V while the frequency is 50 Hz.
The electrical system, at the connection point, must include an earth connection as required by the Regulations 73//23 EEC and 93/98 EEC.
07.2 EXTERNAL THERMOSTAT
In these heating stoves it is possible to install an external thermostat. This operation may only be performed by authorised personnel. Use a 2-pole cable with
everyday double insulation. In the event that the thermostat is closed, the stove functions at the power set. If the thermostat opened, the stove would work in
MODULATE mode until the thermostat closes.
08. ELECTRONICS WITH HYDRO STOVE 6-BUTTON LCD DISPLAY
08.1 CONSOLE
Figure 1 describes the meaning of the status indicators appearing on the display left side.
The control panel shows the information concerning the stove status. Several types of data can be displayed and the settings available according to the access
level can be modified by entering the menu.
Depending on the operating mode, the displays can take on different meanings depending on the position on the display.
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Eva Calor Sola wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.