1.Safety warnings
Installation and connection must be carried out by qualified staff in compliance with local regulations, national and
European standards (UNI 10683) and with the installation instructions contained herein. The electrical system of the
room where the stove is to be installed must comply with current regulations.
The combustion of waste, especially of plastic materials, damages the stove and the vent pipe. Moreover, it is
forbidden by the law against the emission of harmful substances.
Do not use alcohol, petrol or other highly inflammable liquids to light the fire or poke it during operation.
EVA CALOR stoves are manufactured in compliance with:
89/106/EC Directive (Construction products);
2006/95/EC Directive (Low voltage);
2004/108/EC Directive (Electromagnetic Compatibility).
The harmonised standards or the technical specifications (designations) applied according to the
current European safety rules are:
2.Installation instructions
Follow the instructions below before installing your stove.
Select the position where the stove is to be installed and:
Arrange the connection to the vent pipe for fume extraction
Arrange the external air intake (combustion air)
Arrange the connection to the earthed mains
The electical system of the room where the stove is to be installed must be earthed, otherwise the control board may
not work properly.
Place the stove on the floor in a convenient position for the connection to the vent pipe and close to the combustion
air intake.
The appliance must be installed on a floor with an adequate loading-bearing capacity.
Should the existing floor not comply with the requirement above, proper measures must be taken (for instance, the
installation of a load distribution plate).
All the structures which can catch fire if exposed to excessive heat must be protected. Floors made from wood or
inflammable materials must be protected using non-combustible materials (e.g. 4mm-thick sheet metal or ceramic glass).
The appliance installation must ensure easy access for cleaning the stove, exhaust pipes and vent pipe.
This appliance is not suitable to be installed on a shared vent pipe.
During normal operation, the stove draws air from the room where it is installed. Therefore, an external air intake
must be positioned at the same height of the pipe located on the stove back. Exhaust fume pipes must be suitable for
pellet stoves and therefore made from coated steel or stainless steel, with a diameter of 8cm and fitted with adequate
gaskets.
The combustion air intake (
Φ
80mm) must be connected directly to the outside or to adjacent rooms provided they are
fitted with external air supply vents (
Φ
80mm) and are not used as bedrooms or bathrooms or, whenever a fire hazard exists,
as storage rooms, garages, combustible material warehouses, etc. The air vents must be placed in such a way that they
cannot be clogged either from the outside or inside and must be protected using a grille, a metal mesh or other suitable
means provided they do not reduce the minimum section.