10.3.1 Stove switching on
Hold down
P4 for a few seconds to switch on the stove. The display shows the message as in Figure 17 when
the stove is on.
fig. 17
10.3.2 Start-up phase
The stove performs all the steps of the start-up phase according to the parameters concerning its levels and times.
10.3.3 Ignition failure
The alarm is triggered when, after the period of time set by Pr01, the fume temperature has not reached the minimum
value admitted (Pr13 parameter) with a gradient equal to 2°C/min.
10.3.4 Working mode
At the end of the start-up phase, if no problems occurred, the stove enters its normal working mode.
Exchangers are enabled if the fume temperature is higher than Pr15. Exchangers no.2 and 3 start working only if they
were previously enabled.
fig. 18
10.3.5 Changing set room temperature
Press P1 and P2 buttons to change the room temperatture. The display shows the current SET
temperature value as in figure 19.
fig. 19