23ENGLISH
SETTINGS
• DATETIME
• LANGUAGE
• DEGREES
See chapter: firSt ignition SettingS
DISPLAY
This menu allows you to adjust the brightness of the display. The values range from OFF, 1 to 20. If set to OFF, the display backlighting is set
to maximum brightness and turns o after a 60 second delay.
The backlighting can be turned on again by pressing any key or if the stove is in alarm status.
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until DISPLAY appears and conrm by pressing key 6.
Use keys 4-5 to set the desired intensity.
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
STAND BY
The STAND BY function, if enabled, is used when stove switch-o is to be controlled by means of an additional thermostat
CONTROLS PROCEDURE
Press key 6.
Press key 3 until SETTINGS appears and conrm by pressing key 6.
Keep pressing key 3 until STAND BY appears and conrm by pressing key 6.
Use keys 4-5 to enable (ON) / disable (OFF).
Press key 6 to conrm and key 1 to scroll back through the menus until the initial page.
J
FOR CORRECT OPERATION, THE SET THERMOSTAT MUST BE SET TO LOWTA.
> SEE CHAPTER ON ADDITIONAL THERMOSTAT SETTINGS
STAND BY FUNCTION ON
If the STAND-BY function is active (ON), if the room temperature exceeds the value of the SET THERMOSTAT + DELTA T OFF, then the stove
will switch o after a preset delay, displaying STAND BY.
When the room temperature is lower than the SET THERMOSTAT - DELTA T ON and after a possible cooling time, the stove switches back on.
STAND BY FUNCTION OFF FACTORY SETTING
If the STAND-BY function is not active (OFF ), if the stove exceeds the set room temperature it will switch to the minimum value, modulating
and displaying MODULATION. When the room temperature is lower than the SET THERMOSTAT the stove goes back to operating at the set
power, displaying WORK.
OPERATION WITH ADDITIONAL THERMOSTAT OPTIONAL
STAND BY FUNCTION OFF FACTORY SETTING
If the STAND-BY function is not active (OFF ), if the stove exceeds the room temperature set on the additional thermostat (contact open) it will
switch to the minimum value, displaying MODULATION. When the room temperature is lower than the value set on the additional thermostat
(contact closed), the stove goes back to operating at the set power, displaying WORK.
STAND BY FUNCTION ON
When the STAND-BY function is active (ON), when the room temperature set on the additional thermostat has been reached (contact open),
the stove will switch o after a preset delay, displaying STAND BY.
When the room temperature is lower than the value set on the additional thermostat (contact closed) and after a possible cooling time, the
stove switches back on.
J
WHEN STAND BY AND AIR ZONE CONTROL ARE ACTIVE, THE GENERATOR IS SWITCHED OFF ONLY IF BOTH ROOMS
INSTALLATION, DUCTING REACH THE SET TEMPERATURE.
23

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Extraflame DAHIANA VFS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Extraflame DAHIANA VFS

Extraflame DAHIANA VFS Bedienungsanleitung - Deutsch - 36 seiten

Extraflame DAHIANA VFS Bedienungsanleitung - Holländisch - 36 seiten

Extraflame DAHIANA VFS Bedienungsanleitung - Französisch - 36 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info