26 ENGLISH
alaRMs
Display explanation solution
Indicates the presence of an alarm.
On: indicates the presence of an alarm
O: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
fuMes failuRe
Fault related to the ue gas exhaust
motor.
The restoration operations must be carried out by an authorised
technician.
fuMes pRoBe
Fault related to the fumes probe.
The restoration operations must be carried out by an authorised
technician.
fuMes
oveRteMp al.
The ue gas temperature has
exceeded 310°C
Check the pellet ow (see “Pellet feed adjustment”).
Check that the machine is clean, including the fumes route.
Do not rest cloths on the machine.
Other restoration operations must be carried out by an authorised
technician.
Clean CHeCK up 1 - 2
(1 = in BuRning pHase)
(2 = in opeRant pHase)
The combustion chamber or burn pot
bottom are dirty.
The door is not closed correctly.
The ash pan is not closed correctly.
The depression sensor is faulty.
The ue exhaust pipe is blocked.
Incorrect installation
Make sure the holes at the burn pot bottom are completely free.
Check cleanliness of the fumes pipe and the combustion chamber.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Other restoration operations must be carried out by an authorised
technician.
DepR
alaRM
The mechanical depression sensor
has tripped
Contact after-sales centre
no
ignition
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
Check for the presence of pellets in the feed-box.
Adjust the pellet ow (see “Pellet feed adjustment”).
Check the procedures described in the “Ignition chapter.
Other restoration operations must be carried out by an authorised
technician.
no ignition BlaCK
out
No power during the ignition phase.
Switch the stove to OFF using key 1 and repeat the procedure
described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
no pellets
In the work phase, the t° of the ue
gases has dropped below factory
parameters
Check for the presence of pellets in the feed-box.
Regulate the pellet ow.
Other restoration operations must be carried out by an authorised
technician.
Cooling stanD-By
Attempt to release the alarm with
stove still in cooling mode.
Every time the stove displays one of the alarms listed above it will
switch-o automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and STANDBY alternately on the display.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
DepR sensoR
DaMage
Component disconnected or faulty Contact after-sales assistance
CoMManD augeR
alaRM
Abnormal functioning
of pellet feeding
Contact after-sales assistance
26

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Extraflame Ketty Evo wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Extraflame Ketty Evo

Extraflame Ketty Evo Bedienungsanleitung - Deutsch - 32 seiten

Extraflame Ketty Evo Bedienungsanleitung - Holländisch - 32 seiten

Extraflame Ketty Evo Bedienungsanleitung - Französisch - 32 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info