alaRMs
Display eXplanaTion soluTion
Indicates the presence of an alarm.
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset only if the fumes motor has stopped and 15 minutes have
passed since the alarm was displayed, by pressing the key 1/ for 3 seconds.
fuMes MoToR
faulT Fumes motor fault Contact after-sales centre
fuMes pRoBe Fumes probe fault. Contact after-sales centre
HoT fuMes High fumes temperature Check pellet feed (see “Easy setup”), if the problem cannot be solved,
contact a qualied technician.
no
iGniTion
The pellet hopper is empty.
Pellet feed calibration inadequate.
Check for the presence of pellets in the hopper.
Adjust the pellet ow (see “Easy setup”).
Check the procedures described in the “Ignition chapter.
no flaMe
The pellet hopper is empty.
No pellet feed.
The gearmotor does not feed pellets.
Check for the presence of pellets in the hopper.
Adjust the pellet ow (see “Easy setup”).
DepR alaRM
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked/dirty
The air intake pipe is blocked/dirty
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Check/clean air inlet.
* TRapDooR BlockeD
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
The ash drawer is not closed correctly.
Check that the door closes correctly.
Check that the burn pot is clear and clean. The automatic cleaning of the
burn pot is blocked.
If the problem persists, contact the service centre.
Check hermetic closure of the ash drawer.
* pRessuRe sensoR
DaMaGe
Dierential pressure sensor faulty, disconnected
or broken. Contact after-sales centre
* auGeR conTRol
alaRM Abnormal pellet feeding. Contact after-sales centre
* auGeR BlockeD Abnormal operation of pellet motor. Contact after-sales centre
* eMpTy HoppeR
The pellet hopper is empty.
The door is not closed correctly.
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The fumes exhaust pipe is blocked.
Check for the presence of pellets in the hopper.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air
channel and the combustion chamber.
Contact after-sales centre
MaX elecTRical cuR-
RenT
The automatic cleaning of the burn pot is
blocked.
Burn pot dirty/clogged
The door is not closed correctly.
Check that the door closes correctly.
Check that the burn pot is clear and clean.
The automatic cleaning of the burn pot is blocked.
If the problem persists, contact the service centre.
cHaMB pRoBe Chamber probe fault. Contact the after-sales centre.
TO FIND OUT WHERE YOUR NEAREST SERVICE CENTRE IS, CONTACT YOUR DEALER OR GO TO THE WEBSITE WWW.LANORDICA-EXTRAFLAME.COM
36

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Extraflame SINFONY wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Extraflame SINFONY

Extraflame SINFONY Bedienungsanleitung - Deutsch - 40 seiten

Extraflame SINFONY Bedienungsanleitung - Holländisch - 40 seiten

Extraflame SINFONY Bedienungsanleitung - Französisch - 40 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info