C850 532015 Rev. A
FSW OP
FSW CL
RCL
FCCFCO
FSW CL
EF
ROP
INVERTER
L
LIMIT SWITCH UNIT
ENGLISH
To connect the
photocells and
safety devices,
refer to paragraph
11.4.2.
Fig. 28
11.4.1 TERMINAL BOARD J1 - ACCESSORIES (FIG. 28)
J6=FCC - FCO - Manoeuvre stop command.
J5=RCL - Start of closing deceleration.
J3=ROP - Start of opening deceleration.
LOOP 1 - LOOP 1 magnetic loop (OPEN - terminals 1-2): for OPENING.
LOOP 2 - LOOP 2 magnetic loop (SAFETY/CLOSE - terminals 3-4): for SAFETY/CLOSING.
EF - Electrical stopping brake for motor locking.
OPEN - “Open” command (N.O. - terminal 5): means any pulse generator (e.g.: button) which, by closing a contact, commands
opening and/or closing of the gate.
CLOSE - “Close” command (N.O. - terminal 6): means any pulse generator (e.g.: button) which, by closing a contact, commands
closing of the gate.
FSW CL - Safety contact when closing (N.C. - terminal 7): he purpose of the closing safety devices when closing is to protect the
area affected by the movement of the gate during the closing phase, reversing the motion. They never trip during the opening cycle.
The CLOSING SAFETY DEVICES, if tripped when the automated system is open, will prevent the closing movement.
If CLOSING safety devices are not connected, jumper terminals FSW CL and GND (Fig. 32).
NOTE: If this connection is made, it will not be possible to use the FAILSAFE control.
STOP - STOP contact (N.C. - terminal 8): means any device (e.g.: button) which, by opening a contact, can stop movement of
the automated system.
If STOP devices are not connected, jumper terminals STOP and GND (Fig. 32).
FSW OP - Safety contact when closing (N.C. - terminal 9): the purpose of the opening safety devices when opening is to protect
the area affected by the movement of the gate during the opening phase, reversing its motion. They never trip during the closing
cycle. The OPENING SAFETY DEVICES, if tripped when the automated system is closed, will prevent the opening movement.
If OPENING safety devices are not connected, jumper terminals FSW OP and GND (Fig. 32).
GND (terminals 10-11-19) - Accessories power supply negative
24 VDC (terminals 12-13) - Accessories power supply positive
The max. load of the accessories is 500 mA. To calculate absorption, refer to the instructions included with
the individual accessories.
OUT 1 - DECELERATION COMMAND (terminal 14): signal telling the inverter that deceleration has begun.
OUT 2 - CLOSE COMMAND (terminal 15): signal telling the inverter that the gate is closing.
OUT 3 - OPEN COMMAND (terminal 16): signal telling the inverter that the gate is opening.
To avoid compromising correct system operation, do not exceed the power indicated in fig. 28.
OUT 4 - Output 4 open-collector +24 VDC (terminal 18): the output can be set in one of the functions described in Advanced
Programming Level (par. 11.5.2.). The default value for ALL PRE-SETTINGS is BUS COMMUNICATION.
Maximum load: 24 VDC with 100 mA.
60 W max
230 V~
230 V
~
50/60 Hz
11.4 ELECTRICAL CONNECTIONS
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für FAAC C850 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info