473606
19
Zoom out
Zoom in
Vorherige Seite
1/60
Nächste Seite
18 < < < <
L
The Gala has a glass back panel, if not desired can this be removed. To do this unscrew the 4 screws
of the back plate, remove the glass and mount the back plate using the 4 screws.
Build up the rest of the surround and ensure that the glass can be removed.
2.4.3 Installation as one sided without surround or as a see through.
The Gala can be built in a wooden casing.
The Gala has a glass back panel, if not desired can this be removed. To do this unscrew the 4 screws
of the back plate, remove the glass and mount the back plate using the 4 screws.
If the Gala will be built in as a see-through, remove the back plate by unscrewing the 4 screws. The
glass is visible.
Ensure that the appliance is levelled, and that the glass can be removed.
The appliance can be screwed to the casing with 2 screws. Ensure that there is adequate ventilation
in the casing.
The Gala is supplied with a MDF drawer which can be painted in every desired colour.
2.5 User manual
2.5.1 Instructions for use
1. First fill the water tank before the appliance is switched on. (see par. 2.8.2).
2. Only pull the drawer in order to operate the fireplace, refill the water tank or replace a light,
otherwise it may lead to a high water level in the collection reservoir, which will lead to a
lower flame effect. If this happens, empty the collection reservoir as indicated in par. 2.9.2.
3. With flame height set to minimum, the water use will be 40 ml per hour, and the appliance
will burn three times as long as when the flames height is set to maximum.
4. Do not move or replace the fireplace while there is water in the water tank or the
collection reservoir.
5. The flames will move more realistically when the button for flame control is turned low.
6. Give the flame generator some time to react to changes when you change the flame effect.
7. If the appliance is not used for a period longer than 2 weeks, empty the water tank and the
collection reservoir en dry them with a cloth.
8. When the water tank is empty the lights will go out and you will hear two beeps. The
fireplace will go into stand-by mode.
9. The lights should be inspected regularly as described in par. 2.8.1.
Depending on the room temperature and humidity some condensation can appear on the inside
of the fireplace. This can be prevented by turning the flame effect lower, just until the glass
has warmed up.
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Faber Gala opti-myst wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info