Installation Instructions Installation Instructions
17
8 Instructions for client
Recommend that the unit should be checked annually by a
qualied specialist to ensure the safe use and to guarantee a
long service life.
Give advice and instructions on care and cleaning of the
glass. Highlight the danger of burnt-in ngerprints.
Instruct the customer on the operation of the appliance and
the remote control, including setting the receiver.
Hand over to customer:
- installation manual
- user manual
- log set instruction card
- suction cups
9 Annual maintenance
9.1 Checking and cleaning:
* Check and clean if necessary after verication:
- the pilot light
- the combustion chamber
- the glass
- the logs for breakage
- the outlet
* Replace, if necessary:
- chips/glass granulate
9.2 Cleaning the glass
Most deposits can be removed with a dry cloth. Clean the glass
with a ceramic hob cleaner.
> Please note:
Avoid ngerprints on the glass. These are no longer removable
after they are burnt in!
Now carry out check-up as described in Chapter 7 “Checking after
installation”.
10 Conversion to other gas type
The conversion to a different gas type may only be performed by a
qualied installer/dealer.
10.1 Conversion from natural gas to propane
(or vice versa)
This can only be done by replacing the burner. To do so, please
contact your dealer.
Specify with your order always the type and serial number of the
device.
11 Flue calculation
A simple way to calculate whether the exhaust conguration is
possible in combination with your re, use the free “Faber Flue App”
and download it from:
INTERNET:
BlackBerry, Android, PC (with Google Chrome browser)
APP store:
iPhone, iPad and Mac.
Google Play:
Android smartphones and Android tablets.
Alternatively use the exhaust calculation table (see chapter 13).
The alternatives of outlet lengths and any restrictors are set out in
the restrictor table. In the table we work with start length (STL), total
vertical height (TVH) and total horizontal length (THL).
Start length (STL):
This is the rst part that is placed on the re and represents a
certain value (g. 12.1, 12.2 and 12.3 A, N and F). This value is in
the top row of the table (see restrictor table 11.1 and 11.2).
Total vertical height (TVH):
TVH is the difference in height measured from the top of the unit to
the outlet; it can be measured or determined from the building plan.
For clarication see the TVH indication in the drawings (g. 12.1,
12.2 and 12.3).
Total horizontal length (THL):
THL is the total horizontal length and consists of elbows and pipes
which are entirely in the horizontal plane. Elbows I, K and Q and
the elements H, J, L, M, P and R (g. 12.1 and 12.2).
Length horizontal plane:
The horizontal length consists of the elements H, J, L, M, P and R
(g. 12.1 and 12.2).
Elbows 90° in the horizontal plane:
Horizontal bends are bends which are entirely in the horizontal
plane (g. 12.1, 12.2 and 12.3 I, K and Q).
Bends 45° or 30° in the horizontal plane:
Horizontal bends are bends which are entirely in the horizontal
plane.
Elbows 90° vertical to horizontal plane:
These are 90° elbows, which proceed from horizontal to vertical
(g. 12.2 and 12.3 G, O and S).
Bends 45° or 30 °vertical to horizontal plane:
These are 30° or 45° bends with a vertical offset of less than 45°
(g.12.1 B and D).
Pipes under a tilt angle:
These are pipes which are vertically ascending at an angle of 30°
or 45° (g. 12.1 C). Fill in only in combination with at least 2x 30 or
45° bends in the vertical part.
Restrictor table:
See the restrictor table at the right vertical (TVH) and horizontal
length (THL).
For “x” and if the values are outside the table, then the combination
is not allowed. Only then adjust the TVH or THL.
If a value is indicated, check that the calculated STL value is not
lower than indicated in the table. In this case STL must be adjusted.
The found value indicates the width of the restrictor (“0” means no
restrictor). Standard is a restrictor of 30mm installed (see g, 2.0 F,
rst remove hatch “G”).
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Faber MATRIX 1050-500 II wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Faber MATRIX 1050-500 II

Faber MATRIX 1050-500 II Installationsanweisung - Deutsch - 52 seiten

Faber MATRIX 1050-500 II Installationsanweisung - Holländisch - 48 seiten

Faber MATRIX 1050-500 II Installationsanweisung - Französisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info