Installation Instructions Installation Instructions
15
4.4.1 Hanging on the wall 800/500-650-IIL, -IIR and -III
The appliance can be wall-mounted with the optional wall bracket
(see g. 1.8).
4.5 Installing the ue materials
When penetrating a non-combustible wall or ceiling the
opening must be at least 5mm larger than the diameter of the
discharge material. At a combustible wall or ceiling is this
100mm larger than the diameter of the drainage material.
Horizontal sections should be installed with a slope towards
the re (3 degrees).
Build the system from the re. If this is not possible you can
make use of an extendable adapter section.
For truing up the exhaust system use the 0,5m. pipe, which
can be shortened and ensure that the inner pipe is always
2cm longer than the outer pipe.
Parts, which are shortened, must be secured with a
self-tapping screw.
Wall and roof terminals can also be cut.
Do not insulate but ventilate built-in ue material (approx.
100cm²).
4.6 Constructing the false chimney
If possible, carry out a performance test at the re before nally
nishing the installation.
4.6.1 False chimney
* Construct the false chimney of non-combustible material in
combination with metal proles or of masonry/concrete
blocks.
* Be aware of ventilation grids and service door (see g. 1.0 to
1.5). Place above the ventilation grids a screen plate made of
non-combustible material (see g. 1.1, 1.3 or 1.5)
* Always use a lintel or reinforcing bars while bricking the
outlet. They should not be placed directly on the re.
* Built the false chimney against the appliance (see g. 1.0 to
1.5). Keep a minimum distance of 2mm between the false
chimney and the appliance, because of the extension of the
appliance.
4.6.2 Installation and nishing
For installation and nishing the following points are of interest:
H = moldings (g. 2.4 and 2.7)
I = distance prole (g. 2.4)
J = upper side ange combustion chamber (g. 2.5)
K = distance holder/glass support (g. 2.6)
L = distance holder/glass support (g. 2.6)
> Please note:
Ensure that the re is not load-bearing with regard to the false
chimney breast.
4.6.3 Method I with cover strip (g. 2.2)
Build the false chimney breast or plateau against the moldings H
and distance proles I (see g. 2.4 and 2.7).
Keep a minimum distance of 2mm between the false chimney and
the appliance, because of the extension of the appliance. Take into
account the thickness of the nish!
4.6.4 Method II with built-in strip (g. 2.3)
Remove the distance proles “I” (see g. 2.4).
Make sure that the screws of the front distance prole “I” will be
replaced, in order to ensure the air tightness of the appliance.
Build the plateau against the glass supports K and L (see g. 2.6).
Keep a minimum distance of 2mm because of the extension of the
appliance.
For the height of the plateau see point “J” (g. 2.5).
5 Removing the glass
5.1 Removing the glass from the front
MatriX 800-I:
Remove the moldings “A” left and right (g. 3.0).
Turn the left and right side clamps “B” up (g. 3.0).
Place the suction cups on the glass and slide the upper list
“C” up (g. 3.1).
See g. 3.2, number:
1. Slide the glass to the top so that the bottom will
release.
2. Now, carefully slide the glass to the left.
3. Get the released side towards to you and put the glass
on a safe place.
MatriX 800-II:
Remove molding “A” left or right (g. 3.0).
Turn the left or right side clamps “B” up (g. 3.0).
Place the suction cups on the glass and slide the upper list
“C” up (g. 3.3).
See g. 3.3, number:
1. Slide the glass to the top so that the bottom will
release.
2. Now, carefully slide the glass to the left or to the right.
3. Get the released side towards to you and put the glass
on a safe place.
MatriX 800-III:
Place the suction cups on the glass and slide the upper list
“C” up (g. 3.3).
See g. 3.3, number:
1. Slide the glass to the top so that the bottom will
release.
4. Get the released side towards to you and put the glass
on a safe place.
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Faber MATRIX 800-500 RD wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Faber MATRIX 800-500 RD

Faber MATRIX 800-500 RD Installationsanweisung - Deutsch - 52 seiten

Faber MATRIX 800-500 RD Installationsanweisung - Holländisch - 48 seiten

Faber MATRIX 800-500 RD Installationsanweisung - Französisch - 48 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info