1 Dear user
Congratulations on purchasing your Faber product, a quality
product that will provide you with the warmth and atmosphere for
many years. Please read the user manual before using the fire.
Should a malfunction occur despite the careful final checks, then
you can always contact your Faber dealer.
Please note:
The data of your fire is available in the user manual.
Only have the appliance installed by a qualified installer according
to the gas safety regulations.
Read this installation manual properly.
Check the fire for transport damage and report any damage
immediately to your dealer.
Glen Dimplex Benelux certifies that this Faber fire complies with the
essential requirements of the gas appliances directive.
Product: gas room heater
Model: MatriX 800/500-I/IIL/IIR/III
MatriX 800/650-I/IIL/IIR/III
Applicable EC directives: 90/396/EEC
Harmonized standards applied: NEN-EN-613 and NEN-EN-613/A1
This declaration is invalid, if without the written permission of Glen
Dimplex Benelux:
Changes are made to the appliance.
The fire is connected to other exhaust materials than
specified.
2 Safety instructions
The unit must be installed and subsequently serviced every
year and maintained in accordance with these instructions
and the applicable national and local regulations.
Ensure that the data on the type label matches the local gas
type and pressure.
The settings and the construction of the fire must not be
changed!
Do not place extra imitation wood or other smoldering
material on the burner or in the combustion chamber.
The appliance is for atmosphere and heating purposes. This
means that all surfaces, including the glass, can be very hot
(over 100°C). Exceptions to this are the bottom of the fire
and the control elements.
Do not place any combustible materials within 0,5m of the
radiation area of the fire.
Through the natural air circulation of the fire moisture and
uncured volatile components from paint, building materials
and carpeted floors, etc. are attracted. These parts can settle
as soot on cold surfaces. Therefore do not light the fire
shortly after installation.
Light the fire for the first time and run for several hours on the
highest setting, so that the paint can cure. Provide adequate
ventilation, so that any fumes can disperse; we recommend
vacating the room during this process.
> Please note:
1.
All transport packaging is removed.
2.
No children and pets in the room present.
3 Installation requirements
This device can be built into an existing or new chimney.
For devices with flexible gas pipes, the gas regulator block is
mounted on the right side of the fire for transport reason (fig 1.6).
The gas regulator block with the receiver and the I.T.C. must be
placed on a distance of max. 30cm behind a service door.
The false chimney should be of non-combustible material.
The space above the fire should always be ventilated using
the supplied grids or a similar alternative with minimal free
passage of 200cm² per grid.
The false chimney breast and its construction may not rest on
the appliance.
It is not permitted to start directly on the device with
concentric cut down pipe material.
The air supply could then possibly be closed.
For the supply of the combustion air and the discharge of the
combustion gases you should always use the Flue materials
specified by Faber. Only when using these materials can
Faber guarantee the safe and proper operation of the
appliance.
The outside of the concentric flue material can heat up to
+/-150°C. Ensure, when penetrating a flammable wall or
ceiling, construction with proper insulation and protection.
And ensure respective distance.
Ensure for great discharge lengths that the concentric
discharge material is supported every 2m, so that the weight
of the material is not supported by the fire.
It is not permitted to start directly on the device with
concentric cut down pipe material.
The air supply could then possibly be closed.
1.1 Introduction
1.2 Please check
1.3 CE Declaration
3.1 Fire
3.2 False chimney breast or other structure
3.3 Flue pipe and terminal requirements
Downloaded from www.Manualslib.com manuals search engine
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Faber MatriX 800-serie wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info