It is not necessary to take out the glass from the side to place the
log set or for maintenance.
800/500-650-IIL, IIR and III
• First, remove the front glass (see Chapter 5.1).
• Remove the left or right clamp strip on the top (fig. 3.4).
• Place the suction cups on the glass (fig. 3.5).
• See fig. 3.5, number:
1. Slide the glass towards to you and to the top so the
bottom and back side will release.
2. Now, carefully get the underside towards to you and
put the glass on a safe place.
> Please note:
Replace the glass in reverse order.
Clean all fingerprints on the glass; otherwise they will burn in once
the fire is used.
6 Placing the decoration material
It is not permitted to use other or to add more material in the
combustion chamber.
Keep the pilot light always free of decoration material!
See fig. 4.0 to 4.5 or the included log set card:
• Divide the glass granulate on the perforated bottom plate.
• Place the 2 large wood blocks and make sure there is no
glass granulate underneath.
• Place the other wood blocks.
• Divide the chips on the glass granulate and the perforated
bottom plate.
• Start the fire as described in the user manual.
• Assess whether the flame distribution and the Symbio-effect
is good. Move or remove any chips/glass granulate to a good
Symbio-effect.
• Replace the glass (Chapter 5) and check the fire image.
7 Checking the installation
Check that the burner pressure and primary pressure match with
the information listed in the manual, Chapter 14 “Technical
specifications”.
Measuring the primary pressure:
• Close the shut-off valve.
• Turn measuring nipple B (see fig. 1.7) some turns open and
connect a measuring hose to the gas regulator.
• Take this measurement at highest setting of the fire and when
the fire is set to pilot light.
• Do not connect the unit if the pressure is too high.
Measuring the burner pressure:
Check the burner pressure only with proper primary pressure.
• Turn measuring nipple A (see fig. 1.7) some turns open and
connect a measuring hose to the gas regulator.
• The pressure must correspond to the value indicated in the
technical specifications of this manual. In case of deviation contact
the manufacturer.
> Please note:
Close all pressure measuring nipples and check for gas leakage.
Let the fire burn for at least 20 minutes at highest setting and check
the flame for:
*
Flame distribution
*
Color of the flames
If one or both points are not acceptable then check:
• The log set layout and/or the amount of glass granulate/chips
on the bottom plate.
• The pipe connections for leaks (in case of blue flames).
• Whether the correct flue restrictor is fitted. (see fig, 2.0 F, first
remove hatch “G”).
• The outlet.
- Wall terminal right side up
- Roof terminal on the right position
- If the maximum horizontal flue lengths is not exceeded.
• Check that the pilot flame is well above the main burner and
not covered by chips.
• Check the ignition of the main burner on full and small
setting. (Ignition must be smooth and quiet).
Check with a gas leak finder or spray all connections and pipes for
gas leakage.
If you are in possession of a CO/CO2 flue gas analyzer, then it is
possible to check the supply air and the combustion gases.
There are two measuring pipes at the front of the fire between the
mounting frame and the glass (fig. 2.1).
The ratio CO2 and CO must not be greater than 1:100.
Example:
CO2 is 4% and CO is 400ppm, measured at the highest point.
If the ratio is greater than 1:100 or exhaust gases are measured in
the supply air, then also check above points.