12
1/ INSTALLING YOUR APPLIANCE
CHANGING THE GAS SUPPLY
Proceed as follows every time you change the
gas supply:
— Modify the gas connection
— Change the injectors
— Adjust the hob connections.
•
Modify the gas connection : refer to the
“Gas Connection” section.
•
Change the injectors, proceed as follows:
—
Remove the pan supports, heads and
covers from all burners.
For a 3-ring burner :
—
Use a 7mm type pipe spanner (not
supplied).
For other burners:
—
Use the spanner provided.
—
Unscrew and remove the injectors located
in the base of each crucible
(Fig. 01).
—
Replace with the corresponding gas
injectors, in compliance with the injector
positioning markers and the gas
characteristics table at the end of this chapter;
proceed as follows:
—
First, manually tighten until the injector
locks into place.
—
Fully connect the spanner onto the injector.
—
Draw a line on the burner plate using a
pencil where shown
(Fig. 02).
—
Turn the spanner clockwise until the line
appears on the opposite side
(Fig. 03).
Warning
Exceeding this limit may damage the
product.
•
Fig. 02
Fig. 03
Line
Line
Fig. 01
Spanner
Injector
Crucible
Warning
- For the following references : CFI-
4GLSTANAT* - CFI-3GLSTANAT*, your hob
is delivered set-up for
nnaattuurraall ggaass
.
- For the following references : CFI-
4GLSTABUT* - CFI-3GLSTABUT* - 2MCF-
2GSAXBUT*, your hob is delivered set-up for
bbuuttaannee ggaass
.
The injectors which are needed to change
the gas can be found in the installation
guide pouch.
Warning
Exceeding this limit may damage the
product.
-
Reposition the burner heads, burner covers
and pan supports on the hob.
Tip
Each time you change the gas supply,
tick the box corresponding to the new gas
level on the label found in the instruction
guide pouch.
Refer to the corresponding “Gas
Connection” section.
Spanner
Spanner